Cobra CPI 480 Operating Instructions Manual

Cobra CPI 480 Operating Instructions Manual

400 watt power inverter
Hide thumbs Also See for CPI 480:

Advertisement

Operating Instructions
400 WATT POWER INVERTER
CPI 480
Printed in China
Part No. 480-523-P
Version A
Nothing Comes Close to a Cobra
®

Advertisement

Table of Contents
loading

Summary of Contents for Cobra CPI 480

  • Page 1 Operating Instructions 400 WATT POWER INVERTER CPI 480 Printed in China Part No. 480-523-P Version A Nothing Comes Close to a Cobra ®...
  • Page 2: Introduction

    Our Thanks to You Introduction Our Thanks to You Thank you for purchasing the Cobra CPI 480 inverter. Properly used, this Cobra product will give you many years of reliable service. How Your Cobra Power Inverter Works The Cobra power inverter is an electronic product that...
  • Page 3: Product Features

    Product Features Introduction Features • Reverse Polarity Protection • Two AC Receptacles • Low Battery Alarm • Automatic Thermal Protection/Shutdown • Low Battery Shutdown Protection and Power Indicators On/Off AC Outlets USB Outlet Power Switch Negative Battery Positive Battery Cable Terminal Cable Terminal (Black) Cooling Fan...
  • Page 4: Table Of Contents

    Contents Introduction Introduction Our Thanks to You ....A1 Customer Assistance ....A1 Product Features .
  • Page 5: Important Safety Information

    Important Safety Information Introduction Important Safety Information • Before installing and using your Cobra power inverter, please read these general precautions and warnings. Caution and Warning Statements To make the most of this inverter, it must be installed and used properly. Please read the installation and operating instructions carefully before installing and using it.
  • Page 6 Caution: Rechargeable Appliances Certain chargers for small nickel cadmium batteries can be damaged if connected to the Cobra 400 watt inverter. Two particular types of equipment are prone to this problem: 1. Small battery-operated appliances Plug In Directly...
  • Page 7: Quick Evaluation Before Installation

    Cig. Lighter Cable 12 Gauge Cable CAUTION Do not use the cigarette lighter cable for loads higher than 150 watts. When connecting loads larger than 150 watts, please connect the inverter directly to the battery. Nothing Comes Close to a Cobra ®...
  • Page 8: Installation

    Quick Evaluation Before Installation Introduction A test load that can Test Load be plugged into the AC receptacle on the inverter for short term testing at a low power level. To check your inverter’s performance before installation: 1. Turn the inverter off (see page 11 On/Off Switch to Off for details).
  • Page 9: Installation Requirements

    WARNING This unit contains components which can produce arcs or sparks. To prevent fire or explosion, do not install in compartments containing a battery or flammable materials, or in a location which requires ignition protected equipment. Nothing Comes Close to a Cobra ®...
  • Page 10: Mounting

    Mounting and Connecting Cables Installation Mounting • To mount your inverter: 1. Place the inverter on a flat surface with the mounting bracket against the mounting surface. Mounting Brackets 2. Mount to secure surface using mounting hardware that is corrosion resistant (not included). Mounting Hardware The inverter can be mounted horizontally or vertically.
  • Page 11 Such damage is not covered by the warranty. CAUTION Remove any jewelry (watch, ring, etc.). Be careful not to short circuit the battery with any metallic object (wrench, etc.). Nothing Comes Close to a Cobra ®...
  • Page 12 You might observe a spark when you make this connection since current can flow to charge capacitors in the inverter. All power connections to your Cobra inverter must be Positive to Positive and Negative to Negative. Connect Power Source...
  • Page 13 Do not make this connection in the presence of flammable fumes. Explosion or fire may result. Thoroughly ventilate the battery compartment before making this connection. Nothing Comes Close to a Cobra ®...
  • Page 14: Power Consumption

    Power Consumption Installation Power Consumption • For each piece of equipment you will be operating from the inverter, you must determine the battery’s reserve capacity (how long the battery can deliver a specific amount of current — in automotive batteries, usually 25 amperes) or ampere-hour capacity (a measure of how many amperes a battery can deliver for a specified length of time).
  • Page 15: Operation

    500 milliamperes from the battery. This is low current draw. It would take more than a week to discharge a 100 ampere- hour battery at this rate depending on the age of the battery. Nothing Comes Close to a Cobra ®...
  • Page 16: Power And Protection Indicators

    Power and Protection Indicators Operation Power and Protection Indicators • The power and protection indicators include a green light, a red light and an alarm. Green Light Power on – The green light should remain on steady. Red Light and/or Alarm Current overload –...
  • Page 17: Operating Limits

    The inverter will also shut down if the input voltage exceeds 15.75V+/-0.75V. This protects the inverter against excessive input voltage. Although the inverter has protection against over-voltage, it may still be damaged if the input voltage were to exceed 16 volts. Nothing Comes Close to a Cobra ®...
  • Page 18: Troubleshooting Guide

    Troubleshooting Guide Operation Troubleshooting Guide • Problem/Symptom Possible Causes Solution Low output voltage Overload Reduce the load. No output voltage Low input voltage Recharge battery. Check connections and cable. No output voltage Thermal Allow inverter after prolonged use shutdown to cool off. Reduce load, continuous operation input...
  • Page 19: Specifications

    To extend the life of the fan, it will stop when there is no load. The speed of the fan increases as the load increases. The unit is completely insulated in input and output for added safety. Nothing Comes Close to a Cobra ®...
  • Page 20: Warranty

    All implied warranties, including warranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty. Cobra shall not be liable for any incidental, consequential or other damages; including, without limitation, to damages resulting from loss of use or cost of installation.
  • Page 21: Customer Assistance

    Please allow approximately three to four weeks before contacting Cobra for status. If the power inverter is out of warranty, a letter will automatically be sent informing you of the repair charge or replacement charge.
  • Page 22 Traffic Warning Systems Mobile GPS Navigation Systems HighGear ® Accessories CobraMarine ® VHF Radios CobraMarine ® Chartplotters Power Inverters Accessories For more information or to order any of our products, please visit our website: www.cobra.com Nothing Comes Close to a Cobra ®...

Table of Contents