SERVICE MANUAL
Model: CFE629CW
4-2 Error code display and sensor positions
4-2-1 Sensor location description
Malfunction description
Malfunction of the ambient
temperature sensor
Malfunction of the fridge
storage temperature sensor
Malfunction of the freezer
storage temperature sensor
Malfunction of the defrosting
temperature sensor
Malfunction of
communication between the
display panel and the power
board
Malfunction of the fan
4-2-2 Graphic display of the sensor location
Sign
Display
Display position
H SNR
F2
Display panel
R SNR
F3
Display panel
F SNR
F4
Display panel
D SNR
F6
Display panel
/
E0
Display panel
/
E1
Display panel
Issue 2009-12-23
Rev. Ref0912S021V0
Sensor location
The ambient temperature sensor is
located on the display panel
The fridge storage temperature
sensor is located on the right side
of the fridge storage compartment
The freezer storage temperature
sensor is located on the left side of
the freezing air-duct cover
The defrosting temperature sensor
is located on the fin evaporator
/
/
16