Sensitivity; Maintenance Cycles; Temperature; Number Of Units - Gaggia Deco Tecnichal Service Manual

Rofessional coffee machine
Table of Contents

Advertisement

English
The values vary between 0.1÷5 in steps of 0.1 sec.
Press key T1 or key T2 to increase or decrease the values
if the parameters need to be changed.
Use key T5 to review all the values used.

9.9 SENSITIVITY

This function enables the sensitivity level to be set. The
setting is based on the mineral salts content in the mains
water used.
The sensitivity level must be set to HIGH if the water used has
a low mineral salts content. Whereas, the sensitively level
must be set to LOW if the mineral salts content is high.
The display shows the following:
Sensitivity
XXXXX
where XXXXX may be:
Low sensitivity
Medium sensitivity 400KΩ
High sensitivity
Press key T1 or key T2 if the parameters need to be changed.
Pressing key T5 enables the next setting to be accessed.
The machine is pre-set with a MEDIUM sensitivity that covers
the majority of uses.

9.10 MAINTENANCE CYCLES

This function enables the number of cycles which can be
carried out to be set (distributions allowed).
The display shows the following:
Mainten. cycles
XXXXXX
where xxxxxx can be a number from 0000 to 99,000
in steps of 100.
The function is disabled when xxxxxx is equal to 0000.
Press key T1 or key T2 if the parameter needs to be changed.
Pressing key T5 enables the next setting to be accessed.

9.11 TEMPERATURE

This function enables the temperature to be displayed ex-
pressed in °C or °F.
The display shows the following:
Temperature
°X
where °X may be "°C" or "°F".
55
150KΩ
1MΩ
Press key T1 or key T2 if the parameter needs to be chan-
ged.
Pressing the T5 enables the next setting to be accessed.

9.12 NUMBER OF UNITS

This function enables the number of units comprising the
machine to be set.
The display shows the following:
No. of units
X
where X is a value that can be selected from 1÷4
Press key T1 or key T2 if the parameter needs to be chan-
ged.
Pressing key T5 enables the next setting to be accessed.
9.13 UNIT TEMPERATURES
This function enables the temperatures of each single unit
to be set.
The display shows the following:
Unit 2 temp.
XXX°C
where 2 represents the number corresponding to the unit,
XXX is a value that can be selected from 80÷125°C in
steps of 1°C.
Press key T1 or key T2 if the parameter needs to be changed.
Press key T5 to proceed to the next setting.

9.14 PID TYPE THERMOSTAT CONTROL

This function enables the PID thermostat control parameters
to be parameterised. This function is not currently operatio-
nal. A recommendation is made not to change the pre-set
parameters.
The display shows the following:
kP
kI
XX.X
Y.YY
ZZ.Z
where XX.X is the proportional correction constant;
Y.YY is the integrated correction constant;
ZZ.Z is the derivative correction constant.
Press key T5 to proceed to the following setting.
kD