Inputs To The Adf Controller Pcb - Canon DADF-B1 Service Manual

Table of Contents

Advertisement

CHAPTER 2 BASIC OPERATION
B. Inputs to the ADF Controller PCB

1. Inputs to the ADF Controller PCB (1/2)

Feed motor clock sensor
SR1
Pickup unit cover sensor
SR2
Separation sensor
SR3
Original set sensor
U503
Pre-registration sensor
U502
Original width detecting
volume
U508
Last original sensor
U504
2-2
COPYRIGHT © 1999 CANON INC. CANON DADF-B1 REV.0 APR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
3
3
1
3
J6A-3
2
2
2
2
J6FA-2
1
1
3
1
J6FA-1
J101
J1101
11
J6A-4
3
3
1
9
1
1
3
J6FA-6
10
J6FA-5
2
2
2
J102
3
3
4
8
J6A-7
6
1
1
6
J6FA-9
2
2
5
7
J6FA-8
J103
4
4
8
4
J6A-11
3
3
9
3
J6FA-12
2
2
10
2
J6FA-13
1
1
J6FA-14
11
1
5
5
7
5
J6FA-10
J301
J1102
4
2
J6B-6
3
3
J6FB-5
5
5
J6FB-3
4
4
J6FB-4
1
J6FB-7
1
J201
J6B-8
1
3
1
8
2
2
2
7
J6FA-9
J6FA-10
3
1
3
6
J801
4
5
4
4
J6B-12
3
3
6
3
J6FB-13
2
2
7
2
J6FB-14
1
1
8
1
J6FB-15
5
5
4
5
J6FB-11
J401
J1801
Figure 2-102
ADF controller PCB
+ 5V
While the feed motor is rotating,
FMCK
alternates between '1' and '0'.
+ 5V
When the pickup unit cover is
opened, '0'.
SCVR
(When the light-blocking plate is
not at the sensor.)
+ 5V
When an original is detected, '0'.
SPR
(When the light-blocking plate is
not at the sensor.)
+ 5V
+ 24V
When an original blocks the
EMP
sensor, '0'.
EPLED
+ 5V
+ 24V
When the original blocks the
ENT
sensor, '0'.
ETLED
+ 5V
Generates an analog voltage to
WIDE
suit the width of the original placed
on the original tray.
+ 5V
+ 24V
When an original blocks the
LAST
sensor, '1'.
LTLED