Flush Water Valve - Hoshizaki TM-500AAE Service Manual

Thin glass ice maker
Table of Contents

Advertisement

8) Assemble the removed parts in the reverse order of which they were removed.
9) Open the water supply tap.
10) Connect the power source.
11) Check for water leaks.
12) Refit the panels in their correct position.

8. FLUSH WATER VALVE

1) Close the water supply tap.
2) Remove the panels.
3) Push the Stop Button, and after 9 minutes disconnect the power source.
4) Remove the Cover - Water Valve.
5) Remove the Clamp and disconnect the Hose from the Flush Water Valve.
Note: Water may still remain inside the Evaporator. Be sure to drain the water into the
Drain Pan.
6) Disconnect the Terminals from the Flush Water Valve.
7) Remove the Flush Water Valve.
8) Remove the Drain Pipe from the Flush Water Valve.
9) Connect the Drain Pipe to the new Flush Water Valve, and place the valve in position.
10) Connect the Hose to the Flush Water Valve, and secure it with the Clamp.
11) Pour water into the Tank, and check for water leaks on the Flush Water Valve.
12) Open the water supply tap.
13) Connect the power source.
14) Check for water leaks.
15) Push the Stop Button, and make sure water is flushing.
16) Push the Ice Button.
59

Advertisement

Table of Contents
loading

Table of Contents