7. OPERATION BOARD

[a] USER OPERATION (accessible from the Window Panel)
Symbol
Button
Ice
Stop
Reset
Operation
Floor Mounting: When pressed during shutdown, the unit will be
supplied with water and start icemaking operation.
pressed in STOP mode, the unit will start icemaking operation.
Fixed Mounting: When pressed during shutdown, the unit will be
supplied with water. If the storage bin is not full, the unit will
start icemaking operation.
When pressed in ICE mode, the unit will stop icemaking
operation.
After stopping icemaking operation, the unit will
immediately drain and shut down.
When pressed after the unit stops with an error code displayed,
the unit may resume icemaking operation. Unless the cause of
the error has been corrected, the unit may stop again with the
same error code.
Starts and stops the icemaker's operation. To shut down the
unit for a long time, turn this switch OFF in the STOP mode.
The Crankcase Heater will remain energized even with this
switch OFF.
Functions