Dip Switch Functions (Wdr Cameras); Adjustment Method (Wide Dynamic Range Cameras) - Honeywell HD14C4HR6 Installation Manual

Value vandal dome camera
Table of Contents

Advertisement

Dip switch functions (WDR cameras)

Figure 7
Auto Iris level
adjustment. If
necessary, turn
clockwise to increase
brightness level.
Note
The Wide Dynamic Range camera has been designed for the best
wide dynamic performance and can only be used with Vari-focal
Auto Iris lenses.

Adjustment method (Wide Dynamic Range Cameras)

Switch No.
Function
1
EE/DC IRIS
2
AWB/ATW
3
WDR (Wide Dynamic Range)
4
AGC
5
MIRROR
Rev 1.01
Wide Dynamic Range Camera Switch Settings
Line-lock
adjustment
10
Upper locking
screw to set
focus
Lower locking
screw to set
focal length
Video
monitor
Factory (default) settings
output
= ON (up)
Off
On
EE IRIS
DC IRIS
AWB
ATW
Off
On
Off
On
Off
On
= OFF (down)
Document 900.0342
10/05