Appendix 2: Specifications - Magellan MG-6130 Programming Manual

All-in-one wireless security system v2.0
Hide thumbs Also See for MG-6130:
Table of Contents

Advertisement

Event Group #
34 = Special
35 = Non-medical alarm
36 = Zone triggered a utility report
37 = Signal strength weak 1
38 = Signal strength weak 2
39 = Signal strength weak 3
40 = Signal strength weak 4
41 & 42 = Reserved
43 = PGM supervision lost
44 = PGM supervision restored
45 = PGM tampered
46 = PGM tamper restored
47 = Wireless keypad supervision lost
48 = Wireless keypad supervision restored
49 = Wireless keypad battery trouble
50 = Wireless keypad battery trouble restored
51 = Wireless keypad AC failure
52 = Wireless keypad AC failure restored
53 = Wireless repeater supervision lost
54 = Wireless repeater supervision restored
55 = Wireless repeater battery trouble
56 = Wireless repeater battery trouble restored
57 = Wireless repeater AC failure
58 = Wireless repeater AC failure restored
80 = Fire delay started
81= Fire delay cancelled
82 = PGM cold start
83 = Keypad cold start
84 = Repeater cold start

Appendix 2: Specifications

Input Voltage
Max. Current Consumption 1A
Backup Battery
2 PGMs
Standby Battery Life
Temperature Range
Auxiliary Output
Approvals
* It is recommended that you use a 12Vac 1A transformer to power the Magellan console. The console will generate less heat when
connected to a 12Vac transformer than when connected to a 16.5Vac transformer.
† To achieve this value, use a minimum of 15Vdc.
20
12Vac to 16Vac* 20VA or 12Vdc to 18Vdc 1A
7.2Vdc NiMH rechargeable battery pack (order # 0780100178)
PGM1: N.O. solid-state relay (not polarized); Internal resistance 16
100mA
PGM2: One low powered open-collector; Max. handling current 50mA
Minimum 24 hours
0°C to 50°C (32°F to 122°F)
When using an AC or DC power source, the auxiliary output provides 13.8V (200mA maximum)†
When a power failure occurs, the auxiliary output will drop to 7Vdc (backup battery)
00 = System power up
01 = Reporting test
02 = WinLoad logon
03 = WinLoad logoff
04 = Installer in programming mode
05 = Installer exited programming mode
06 = Closing delinquency delay elapsed
99 = Any special event
01 to 16 = User number
99 = Any user number
01 to 32 = Zone number
99 = Any zone number
Reserved
01 to 04 = PGM number
99 = Any PGM number
01 to 04 = Keypad number
99 = Any keypad number
01 to 02 = Repeater number
99 = Any repeater number
01 to 32 = Zone number
99 = Any zone number
01 to 04 = PGM number
99 = Any PGM number
01 to 04 = Keypad number
99 = Any keypad number
01 to 02 = Repeater number
99 = Any repeater number
Sub-group #
(max.): Max. handling current
Programming Guide