CHECKING AND CHARGING THE BATTERY
BATTERY INSTRUCTION
This is a sealed lype 12 volt battery. No liquid level inspection is ever needed and no refilling water will be required.
IMPORTANT:
• Never interfere with the sealed state of the battery.
•Check the charging condition with a voltmeter (Normal charging voltage should be above 12.8V)
•This battery may be installed in an vehicle only If it replaces a similar sealed type battery.
© ® A ® A
=LAMMABLES
SHIELD EVES
A
DANGER
• Do not use at the places near fire. Hydrogen gas generated from battery may cause fire and explosion.
•This 12V battery is only for starting engine. Do not apply for other uses.
• Keep out of the reach of children or the personnel who do not understand the manual. It may cause blindness or severe bum,
•When using the battery, wear safety glasses and rubber gloves. Sulfuric acid may cause blindness or severe bum,
EAS00179

ELECTRICAL SYSTEM

CHECKING AND CHARGING THE BATTERY
w
Batteries generate explosive hydrogen gas
and contain electrolyte which is made of
poisonous and highly caustic sulfuric acid.
Therefore, always follow these preventive
measures:
8 Wear protective eye gear when handling
or working near batteries.
8 Charge batteries in a well-ventilated
area.
8 Keep batteries away from fire, sparks or
open flames (e.g., welding equipment,
lighted cigarettes).
8 DO NOT SMOKE when charging or han-
dling batteries.
8 KEEP BATTERIES AND ELECTROLYTE
OUT OF REACH OF CHILDREN.
8 Avoid bodily contact with electrolyte as
it can cause severe burns or permanent
eye injury.
FIRST AID IN CASE OF BODILY CONTACT:
EXTERNAL
8 Skin — Wash with water.
8 Eyes — Flush with water for 15 minutes
and get immediate medical attention.
INTERNAL
8 Drink large quantities of water or milk
followed with milk of magnesia, beaten
egg or vegetable oil. Get immediate
medical attention.
cC
This is a sealed battery. Never remove
the sealing caps because the balance be-
tween cells will not be maintained and
battery performance will deteriorate.
Charging time, charging amperage and
charging voltage for an MF battery are
different from those of conventional bat-
teries. The MF battery should be charged
as explained in the charging method il-
lustrations. If the battery is overcharged,
the electrolyte level will drop consider-
ably. Therefore, take special care when
charging the battery.