PROBLEM
Motor will not run.
CAUSE
Motor overload protection switch
has tripped
Tank pressure exceeds pressure
switch "cut-in" pressure.
Extension cord is wrong length or
gauge.
Check valve stuck open.
Loose electrical connections.
Possible defective motor or
starting capacitor.
Paint spray on internal motor
parts.
Pressure release valve on
pressure switch has not unloaded
head pressure.
Fuse blown, circuit breaker
tripped.
17 - ENG
CORRECTION
Let motor cool off and overload
switch will automatically reset.
Motor will start automatically
when tank pressure drops below
"cut-in" pressure of pressure
switch.
Check for proper gauge wire and
cord length.
Remove and clean, or replace.
Check wiring connection inside
pressure switch and terminal box
area.
Have checked by a Trained
Service Technician.
Have checked by a Trained
Service Technician. Do not
operate the compressor in the
paint spray area. See flammable
vapor warning.
Bleed the line by pushing the lever
on the pressure switch to the "off"
position; if the valve does not
open, replace switch.
1. Check fuse box for blown fuse
and replace as necessary.
Reset circuit breaker. Do not
use a fuse or circuit breaker
with higher rating than that
specified for your particular
branch circuit.
2. Check for proper fuse. You
should use a time delay fuse.
3. Check for low voltage
conditions and/or proper
extension cord.
4. Disconnect the other electrical
appliances from circuit or
operate the compressor on its
own branch circuit.
D24072