Air Compressor - Craftsman 919.167460 Operator's Manual

Permanently lubricated single stage side stack air compressor
Table of Contents

Advertisement

Available languages

Available languages

PROBLEM
Knocking Noise.
Compressor is not supplying
enough air to operate accessories.
Regulator knob has continuous air
leak.
Regulator will not shut off air
outlet.
D24072
CAUSE
Possible defect in safety valve.
Defective check valve.
Prolonged excessive use of air.
Compressor is not large enough
for air requirement.
Hole in hose.
Check valve restricted.
Air leaks.
Restricted air intake filter
Damaged regulator
Damaged regulator
16 - ENG
CORRECTION
Operate safety valve manually by
pulling on ring. If valve still leaks,
it should be replaced.
Remove and clean, or replace.
Decrease amount of air usage.
Check the accessory air
requirement. If it is higher than
the SCFM or pressure supplied by
your air compressor, you need a
larger compressor.
Check and replace if required.
Remove and clean, or replace.
Tighten fittings.
Clean or replace air intake filter.
Do not operate the air compressor
with the filter removed. Refer to
the "Air Filter" paragraph in the
"Maintenance " section.
Have checked by a Trained
Service Technician.
Have checked by a Trained
Service Technician.

Advertisement

Chapters

Table of Contents
loading

Table of Contents