IR Code Learning 
 
In case none of the code on the code list works for the targeted air 
conditioner, user can use IR code learning function using configuration 
according to below steps:  
 
Step 
Go to configuration setting page on 
the gateway or ZRC‐100 and input 
parameter number "27" and 
parameter value "000" to select the 
dedicated AC code number "000" 
for learning. 
Look up below mapping table (value 
0‐22) for learning, and decide the IR 
setting you intent to learn next.  
For example "22°C, cool" which 
matches value "5" (IR code to be 
learnt will locate at "5" in ZXT‐120). 
Set your original air conditioner 
remote at "22°C, cool" and turn it 
off. (Besides temperature and 
mode, you may set other desired 
settings, such as Fan, Swing etc.)   
Go to configuration setting page on 
the gateway or ZRC‐100 and input 
parameter number "25" and 
parameter value "5" (in this case).  
Press the PROG button on the ZXT‐
120. (this step apply when using 
ZRC‐100 or other portable controller 
for set up, if using gateway, user can 
skip this step) 
Aim the original air conditioner 
remote at ZXT‐120 according to 
below position within 1‐3 inches 
Setup Key 
13
LED Indication Status 
on ZXT‐120 
• LED flashes once  
when ZXT‐120 
receives the 
configuration 
setting 
‐ 
‐ 
• LED flashes once  
when ZXT‐120 
receives the 
configuration 
setting 
• ZXT‐120 is ready to 
learn 
LED flashes twice if 
learning is successful. 
 
LED flashes 6 times if 
it's failed.  