ALARM AND HELP MESSAGES

THER KEYPAD
IN USE
L RM IN
PROGRESS
)
4-5-6 4-3714-,
ALL MANAGER
RESET REQUIRED
ALL ENGINEER
RESET REQUIRED
O E TRIES
NVAL D
OPT ON
nvalid code
ption not
available
ALL ALARM O.
QUOTE ODE XXXXX
O MODULE ADDED
ESC TO CO TI UE

Other Keypad In Use (Galaxy 8 And 18 Only)

This message advises the user that the system is already in use. The Galaxy 8 and 18
allow only one user at a time.

Alarm In Progress

The system is currently in alarm condition and must be cancelled by a valid PIN or
keyswitch operation.

Pa Reset Required

After a PA (Personal Attack) zone has been activated, the system has to be reset by
a high level code (such as a manager or engineer depending on the reset level
setting).

Manager Reset Required

Following an alarm activation, the system requires to be reset by a manager level
code.
This message is displayed when a tamper alarm occurs.

Engineer Reset Required

The system has been programmed for engineer reset following an alarm activation.
The engineer must be called to reset the system before the user can set the
alarm.Tamper alarms usually require an engineer to visit the site to check all
modules on the system.

No Entries

This message appears if a user attempts to view or inspect the log and there is
nothing in the log to be viewed or when the omit option is selected and there are no
omittable zones on the system.

Invalid Selection

The option selected or value entered is illegal or out of range.

Invalid Code

The code entered is not a valid code registered in the system memory.
Option Not Available
This option is provided by the engineer, where it is specifically required. Attempt-
ing to select an option when it has not been provided results in the display of

Technistore Reset

Call the Alarm Monitoring Station and quote the five digit number displayed. Enter
the number quoted by the monitoring station to reset the system.

No Modules Added

When exiting Engineer Mode the panel does not detect the change in the number
of modules. Press esc to continue.