General Information Assembling Vent Pipes - Majestic fireplaces DV360 Operating Manual

Direct vent gas fireplace
Table of Contents

Advertisement

Termination Clearances
Termination clearances for buildings with combustible and noncombustible exteriors.
Inside Corner
A
V
Balcony -
with no side wall
G =
Combustible &
Noncombustible
12"(305mm)
Fig. 16 Termination clearances.

General Information Assembling Vent Pipes

Canadian Installations
The venting system must be installed in accordance
with the current CSA-B149.1 installation code.
USA Installations
The venting system must conform to local codes and/or
the current National Fuel Code ANSI Z223.1/NFPA 54.
Only venting components manufactured by CFM Cor-
poration may be used in Direct Vent systems.
Flex Vent Pipes
Before joining the flex vent pipe to the unit, apply a
bead of high temperature sealant* (provided) to the 4"
pipe exiting the fireplace. Secure flex vent piep in place
with a hose clamp (provided).
*Be sure the flex pipe overlaps at least 1" (25mm) onto
the collars of the fireplace and termination. If the ter-
mination has an internal bead, be sure to overlap and
secure 1" (25 mm) past the bead.
* Be sure the vent is actually crushed before proceed-
ing. Apply a tug to be sure the vent will not slip off the
collars.
20010667
Outside Corner
A =
Combustible
6"(152mm)
V
Noncombustible
2"(50mm)
Balcony -
with perpendicular side wall
G
V
Combustible &
Noncombustible
H = 24"(610mm)
J = 20"(508mm)
DV360/580 Series Direct Vent Gas Fireplace
B =
Combustible
6"(152mm)
Noncombustible
2"(50mm)
B
H
V
J
Repeat process with 7" flex vent pipe. The same proce-
dure must be performed on the vent side.
Fig. 17 Apply high temperature sealant to 4" and 7" pipes.
Recessed Location
D
C
C
E
V
C = Maximum depth of 48"
(1219mm) for recessed
location.
D = Minimum width for back wall
of a recessed location.
Combustible 38"(965mm)
Noncombustible 24"(610mm)
E = Clearance from corner in
recessed location.
Combustible 6"(152mm)
Noncombustible 2"(50mm)
Apply High Temperature
Sealant
Hose Clamp
FP1471
584-15
FP1471
13