KSU INSTALLATION

3.2.6 External Backup Battery Installation

In case of power failure, the external backup batteries automatically maintain uninterrupted power for the ARIA SOHO
System. The external batteries must provide 24V DC; this is generally accomplished by connecting two 12V batteries
in a series arrangement as shown:
NOTE
The cable used to connect the battery is supplied with the KSU.
Battery operation is controlled by the PSU. The PSU will provide charging current to the batteries during normal AC
power operation at a maximum of about 200mA. PSU battery operation will be halted if the AC power is re-connected
or if the battery voltage is too low to maintain full-system operation.
The external batteries can maintain System operation as needed depending on several elements such as battery
charge status, condition and capacity of the batteries, and System configuration (number of Station ports).
CAUTION
It is recommended to use an external backup battery fuse (5A @250V) between the battery and
the System.
Recommended battery capacity is 24V/10AH MF; the ARIA SOHO System should be able to
operate more than 3 hours with batteries that are in good condition.
Carefully check the battery polarity with cable colors (Red and Blue) when connecting the battery
to the System.
Make sure that you do not short out the external batteries and cables.
There is a danger of explosion if external batteries are incorrectly replaced. Replace only with the
same or equivalent type recommended by the manufacturer. Dispose of used batteries according
to the manufacturer's instructions.
FIGURE 3.2.6 EXTERNAL BACKUP BATTERY INSTALLATION