Ariston PC 640 T X AUS Operating Instructions Manual page 6

Table of Contents

Advertisement

Available languages

Available languages

noise, check pressure and adjust at the regulator if
AUS
necessary.
If satisfactory operation cannot be achieved, contact
place of purchase or their appointed agent for
service.
Igniter operation
Check that the igniter for each burner successfully
ignites the gas.
If an igniter fails to work, first remove the plug from
the electrical power outlet, and then check that all
the electrical connections are in place.
If satisfactory operation cannot be achieved, contact
place of purchase or their appointed agent for
service.
Gas Consumption
Rapid Burner
Auxiliary Burner
Semi Rapid Burners
Wok Burner
Total
Gas Connection
Gas Inlet fitting
Location of gas inlet
A
R
S
PC 640 T X AUS
PC 640 N T X AUS
! The product was tested in accordance with AS4551 standard
6
Natural Gas (1.0 kPa)
Ø Injector (mm)
1.24
0.85
1.10
1.19 (x2)
1/2" BSP (male) thread
40 mm from rear edge
40 mm fro
TC
Low flame setting
Check the low flame setting for each hob burner to
ensure that the minimum flame will not be
extinguished by air draughts.
• Light the burner.
• Turn the control until it engages in the minimum
position.
• Ensure the flame is stable and will not be
extinguished by air draughts.
To adjust the minimum flame:
Follow the procedure described in the gas
conversion instruction.
DO NOT MODIFY THIS APPLIANCE IN ANY WAY,
OTHER THAN AS DESCRIBED IN THESE
INSTRUCTIONS.
GC (MJ/hr)
Ø Injector (mm)
7.8
3.6
6.0
13.5
0.70 (x2)
30.9
ULPG (2.75 kPa)
GC (MJ/hr)
9.0
0.80
3.3
0.50
5.5
0.64
13.0
30.8

Advertisement

Chapters

Table of Contents
loading

Table of Contents