Adjusting Method
6-2. POWER ADJUSTMENTS
Video pattern condition: 100 IRE Full White Pattern
Power Adjustment is controlling the panel values set by module maker previously. If there is
problem after power adjustment, classify as a defect and contact PDP module maker.
1. Vs (Vsus Voltage): Sustain Voltage
Measurement equipment : Digital Volt Meter ( DC Volt mode )
Adjusting TP : TP204 (See Picture 6-2)
Adjusting Voltage : The voltage which is written at upper center of DATA BAR in PDP Module.
(Typical Voltage: 175 V, See Picture 6-1)
Picture 6-1. Power Connection and Voltage Adjustment Label
-34-