Indoor Unit
Automatic Operation Button
Press for < 5s to operate Automatic
operation mode.
(Used when the remote control cannot be used.)
Press continuously for 5s or < 10s to
operate Test Run/Pump down. "Beep"
sound will be heard at the 5th second.
(Used when test running or servicing.)
Press continuously for 10s and above to
omit or resume the remote control signal
receiving sound. "Beep, beep" sound will
be heard at the 10th second.
Operation Indication Lamps (LED)
(Green) ......... Lights up in operation,
Operation Mode
Heating, Cooling, Soft Dry and Automatic
Mode.
Random Auto Restart Control
• Operation is restarted randomly after power
failure at previous setting mode.
Anti-Freezing Control
Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Indoor Fan Speed Control
High, Medium and Low.
Automatic Fan Speed Mode
– Heating : Fan speed varies from Me
– Cooling : Fan rotates at Hi, Me and SLo
– Soft Dry : Fan rotates at Lo- speed.
blinks in Automatic
Operation Mode judging.
SSLo in accordance with
indoor heat exchanger.
speed. Deodorizing control is
available.
Deodorizing control is
available.
www.ilmalämpöpumput.com
CS-PW9CKE / CU-PW9CKE / CS-PW12CKE / CU-PW12CKE
Airflow Direction Control
Automatic air swing and manual adjusted
by remote control for vertical airflow.
Manually adjusted by hand for horizontal
airflow.
Starting Current Control
Fan motor is delayed for 1.6 seconds when
compressor starts simultaneously.
Time Delay Safety Control
Restarting is inhibited for appro. 3 minutes.
7 Minutes Time Save Control
Cooling Operation only.
30 Minutes Time Save Control
Heating Operation only.
Hot-Start Control
At Heating Operation the indoor fan will
operate at SLo speed when indoor heat
exchanger temperature reaches 30C.
Anti Cold Draft Control
The indoor fan operates at SSLo when the
indoor heat exchanger temperature is low.
(During Heating mode thermal off)