Meyer Sound UPM-1P Operating Instructions Manual page 32

Ultra series ultra-compact wide coverage loudspeaker and ultra-compact narrow coverage loudspeaker
Hide thumbs Also See for UPM-1P:
Table of Contents

Advertisement

APPENDIX B
AUDIO INPUT — UPM-1P/UPM-2P
Type
Max. common mode range
Connectors
Input impedance
Wiring
DC Blocking
CMRR
RF filter
TIM filter
Nominal input sensitivity
Input level
AMPLIFIERS — UPM-1P/UPM-2P
Note: The specific functions for each model such as crossover points, frequency and phase response, and driver
protection are determined by the control card installed inside the amplifier.
Amplifier type
Output power
THD, IM TIM
Load capacity
Cooling
AC POWER — UPM-1P/UPM-2P
AC power connector
Voltage selection
Safety agency rated
operating voltage
Turn on/turn off points
Current Draw
Idle current
Max. long-term continuous
current (>10 sec)
Burst Current (<1 sec)
Ultimate Short-Term Peak
Current Draw
Inrush Current
26
Differential, electronically balanced
±15 V DC, clamped to earth for voltage transient protection
Female XLR input and male XLR loop output
10 kΩ differential between pins 2 and 3
Pin 1: Chassis/earth through 220 kΩ, 1000pF,
15V clamp network to provide virtual ground lift at audio frequencies;
Pin 2: Signal +
Pin 3: Signal -
Case: Earth ground and chassis
Differential DC blocking up to max. common mode voltage
>50 dB; typically 80 dB (50 Hz - 500 Hz)
Common mode: 425 kHz low-pass; Differential mode: 142 kHz
Integral to signal processing (<80 kHz)
0 dBV (1 V rms, 1.4 V pk). 0 dBV continuous average is typically the onset of limiting for
pink noise and music.
Audio source must be capable of producing a minimum of 20 dBV (10 V rms, 14 V pk)
into 600 Ω in order to produce maximum peak SPL over the operating bandwidth of the
loudspeaker.
Two-channel complementary MOSFET output stages class AB/bridged
350 W total
Note: Amplifier wattage rating is based on the maximum unclipped burst sine-wave rms
voltage the amplifier will produce in to the nominal load impedance low and high channels
30 V rms (42 V pk) into load impedance.
< .02%
4 Ω low-frequency channel, 8 Ω high-frequency channel
Convection
PowerCon with looping output
External 115/230 V AC switch (100 V option available)
115 V AC - 240 V AC
Recommended voltage: 105 V AC - 130 V AC (115 V AC); 210 V AC - 260 V AC (230 V AC);
no turn-off, only fuse protected above 135 V AC and 265 V AC
(For 100 V AC version 90 V AC - 100 V AC recommended, 115 V AC max)
0.13 A rms (115 V AC); 0.065 A rms (230 V AC); 0.15 A rms (100 V AC)
1 A rms (115 V AC); at 0.5 A rms (230 V AC); 1.2 A rms (100 V AC)
1.3 A rms (115 V AC); 0.65 A rms (230 V AC); 1.5 A rms (100 V AC)
2.9 A pk (115 V AC); 2 A pk (230 V AC); 3.3 A pk (100 V AC)
18 A pk (115 V AC); 12 A pk (230 V AC); 15 A pk (100 V AC)