Preparation For The Dive And Function Check; Overview Aladin One Settings - Uwatec Aladin ONE Operating Manual

Hide thumbs Also See for Aladin ONE:
Table of Contents

Advertisement

3 Preparation for the dive

3.2 Preparation for the dive and function check

DEPTH
DIVE TIME
NO
AMPM
DESAT
NO STOP
DECO
STOP
STOP
CNS O
%
2
S
L
O
W
WARNING
3.3 Overview Aladin
®
Configure Aladin
ONE with SmartTRAK according to your needs.
®
Setting
• Setting the gas mixture
• Time limit to reset the O
• Unit system
• Reset desaturation
• UTC (Universal Time Change) zone
• Time of day
• 24 or AM/PM setting
• Date
• Display contrast
UTC (Universal Time Change) zone: this setting allows you to set the watch to a new time zone without
affecting the actual time setting.
Resetting the remaining saturation
WARNING
12
Check the display:
Switch on Aladin
ONE by bridging the water contacts and check the test dis-
®
play: Are all elements of the display activated? Do not use Aladin
display does not show all elements.
Check the displayed O
It is absolutely necessary to check the set mixture before each dive and to
compare it to the gas mixture currently used. Always remember: setting an
incorrect mixture carries an inherent risk of decompression sickness and/or
oxygen toxicity! Maximum deviation from the measured mixture must not
exceed 1% O
. An incorrect gas mixture can be lethal!
2
ONE settings
Range
21-50% O
% mix to air
no reset / 1 - 48 hrs.
2
metric/imperial
on / off
±13 hrs., increments: 15 min.
hours:minutes
1 (low) -12 (high)
Diving after a reset of the remaining saturation may lead you into potentially
hazardous situations which could result in death or serious injury.
After a reset of the remaining saturation do not dive for at least 48 hours.
If you dive after resetting the remaining saturation the computer will miscal-
culate your decompression, which may result in serious injury or death.
Reset the remaining saturation only if you know you will not be diving, flying
or going to higher altitude for the next 48 hours.
Resetting the desaturation should only be done when there is a valid reason,
e.g. loaning the computer to somebody who has not dived in 48 hours or
more. When the computer itself has remaining saturation you must assume full
responsibility for the consequences of resetting the remaining saturation.
% mix:
2
2
ONE if the
®
Default
Page
21% O
->11
2
no reset
no reset
->12
GMT
->8
4
III UWATEC
Aladin
®
®
ONE

Hide quick links:

Advertisement

Table of Contents
loading