Omron Comp Air Elite NE-C30-E Instruction Manual

Omron Comp Air Elite NE-C30-E Instruction Manual

Compressor nebuliser
Hide thumbs Also See for Comp Air Elite NE-C30-E:

Advertisement

Compressor Nebuliser
NE-C30-E
Model
• Instruction Manual
• Mode d'emploi
• Gebrauchsanweisung
• Manuale di istruzioni
• Manual de instrucciones
• Gebruiksaanwijzing
• РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
TM
EN
FR
DE
IT
ES
NL
RU
AR
IM-NE-C30-E-02-11/06

Advertisement

Table of Contents
loading

Summary of Contents for Omron Comp Air Elite NE-C30-E

  • Page 1 Compressor Nebuliser NE-C30-E Model • Instruction Manual • Mode d’emploi • Gebrauchsanweisung • Manuale di istruzioni • Manual de instrucciones • Gebruiksaanwijzing • РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ IM-NE-C30-E-02-11/06...
  • Page 2: Table Of Contents

    Before using the unit Contents Before using the unit Introduction ....................3 Important safety instructions............... 4 1. Know your unit ..................8 2. Guide to using the Comp Air Elite............10 Operating instructions 3. Preparing the nebuliser for use ............11 3.1 Connecting the AC adapter..............
  • Page 3: Introduction

    Introduction Thank you for purchasing the OMRON Comp Air Elite. This product was developed in conjunction with respiratory therapists for the successful treatment of asthma, chronic bronchitis, allergies and other respiratory disorders. The compressor forces air to the nebuliser. When the air enters the nebuliser, it converts the prescribed medication into an aerosol of microscopic droplets that can easily be inhaled.
  • Page 4: Important Safety Instructions

    Important safety instructions Read all the information in the instruction manual and any other literature included in the box before using the device. When using an electrical product, especially when children are present, basic safety precautions should always be followed including the following: Warning: Indicates a potentially hazardous situation which, if not avoided, could result in serious injury.
  • Page 5 • When using the carrying bag to carry the device and optional rechargeable battery, do not place hair pins or other metal objects in the bag. • Use only original OMRON AC adapter for AC power outlet. Use of unsupported AC adapter may damage the device.
  • Page 6 • Do not misuse the cord of the AC adapter. • Do not wind the cord of the AC adapter around the main unit or AC adapter. • Changes or modifications not approved by OMRON Healthcare will void the user warranty.
  • Page 7 Important safety instructions General Safety Precautions: • Inspect the device and parts before using them each time, and check that there are no problems. In particular, be sure to check the following: - That the vaporiser head, nozzle or air tube are not damaged. - That the nozzle is not blocked.
  • Page 8: Know Your Unit

    1. Know your unit A4 A5 Rear View Bottom View A. Compressor (Main Unit) D. Inhalation Attachments A1. Power Indicator D1. Mouthpiece A2. Power Switch D2. Adult Mask (PVC) A3. Charge Indicator D3. Child Mask (PVC) A4. Air Connector D4. Nosepiece A5.
  • Page 9 1. Know your unit Accessories F. Spare Air Filters x 5 I. Instruction Manual G. AC Adapter J. Warranty Card G1. Power Connector G2. Power Cord H. Carrying Bag Material of attachment Nebuliser Kit, Mouthpiece, Nosepiece, Adapter for Polypropylene Child Mask (SEBS): Adult Mask (PVC), Child Mask (PVC): Adult Mask (SEBS), Child Mask (SEBS): SEBS...
  • Page 10: Guide To Using The Comp Air Elite

    2. Guide to using the Comp Air Elite Preparing the Nebuliser for Use (Section 3) Note: Clean and disinfect the nebuliser kit and applicable inhalation attachments before using the device for the first time, or if it has not been used for more than one week. Taking Medication (Section 4) Notes: •...
  • Page 11: Operating Instructions

    Operating instructions 3. Preparing the nebuliser for use Warning: Clean and disinfect the nebuliser kit, mouthpiece and optional nosepiece or masks before using them for the first time after purchase, if the device has not been used for a long period of time, or if more than one person uses the same device.
  • Page 12: Adding Medication And Assembling The Parts

    3. Preparing the nebuliser for use Adding medication and assembling the parts Remove the mouthpiece and cap from the nebuliser kit. Remove the inhalation top from the medication tank. Rotate the inhalation top anti-clockwise. Lift the inhalation top out of the medication tank.
  • Page 13 3. Preparing the nebuliser for use Reattach the vaporiser head to the medication tank. Put the inhalation top back inside the medication tank. Align the protrusion on the inhalation top with the indent on the medication tank, as shown. Rotate the inhalation top clockwise and align with the medication tank until they click in place.
  • Page 14 3. Preparing the nebuliser for use Attaching the child mask (PVC) Attach the mask to the inhalation top. Attach the cap to the inhalation air inlet. Attach the child mask to the inhalation top. Attaching the nosepiece Attach the cap when using the nosepiece. Attach the cap to the inhalation air inlet.
  • Page 15 3. Preparing the nebuliser for use Attach the air tube. Attach the air tube to the air connector on the compressor. Attach the other end of the air tube to the air tube connector on the medication tank. Notes: • Make sure that the air tube is securely connected. Otherwise, air may leak from the air tube during use.
  • Page 16: Taking Medication

    4. Taking medication Hold the nebuliser kit as indicated on the right. Caution: Do not tilt the nebuliser kit so that it is at an angle of greater than 45°. Medication may flow into the mouth. ° Press the power switch. The compressor starts and nebulisation starts.
  • Page 17 4. Taking medication Inhale medication according to your doctor’s and/or health care adviser’s instructions. Using the mouthpiece Prepare your mouthpiece according to Section 3.2.7. Insert the mouthpiece into your mouth and inhale the medication breathing normally. Exhale as normal through the mouthpiece. Using the nosepiece Prepare your nosepiece according to Section 3.2.7.
  • Page 18 4. Taking medication When treatment is complete, turn the power off. Check that there is no condensation or moisture in the air tube and unplug the device from the power outlet. Power Outlet Warning: Condensation may occur in the air tube. Do not store the air tube while it contains condensation or moisture.
  • Page 19: Care And Maintenance

    Care and maintenance 5. Cleaning and daily disinfecting Cleaning Following the cleaning instructions after each use will prevent any remaining medication in the tank from drying, resulting in the device not nebulising effectively and also for preventing infections. Warning: Thoroughly rinse the nebuliser and the mask, nosepiece or mouthpiece with clean hot tap water after each use, and disinfect the parts of the nebuliser kit and applicable inhalation attachments after the last treatment of the day.
  • Page 20: Disinfecting The Nebulising Parts

    5. Cleaning and daily disinfecting After cleaning and disinfecting the parts, rinse them thoroughly with clean water and allow the parts to air dry in a clean environment. If the compressor is dirty, wipe it clean with a soft cloth moistened with water or mild detergent. Caution: The compressor is not waterproof.
  • Page 21: Maintenance And Storage

    6. Maintenance and storage To keep your device in the best condition and protect the device from damage follow these directions: Caution: • Do not leave the unit unattended with infants or persons who cannot express their consent. • Do not subject the device or the parts to any strong shocks such as dropping the device on the floor.
  • Page 22: Changing The Air Filter

    Do not boil the air filter cover. Remove the air filter cover, wash it, and make sure it is dry and reattached correctly. • Please contact your OMRON dealer for additional air filters, or if the parts supplied with the device are damaged or missing.
  • Page 23: Troubleshooting

    8. Troubleshooting Check the following if your unit should fail during operation. You can also refer to the pages of this manual for complete instructions. Symptom Cause Remedy Check that the plug is Is the AC adapter connected inserted in an electrical correctly to the an electrical outlet.
  • Page 24 • If the suggested remedy does not solve the problem, do not try to repair the device - no parts of the unit are user serviceable. Return the unit to an authorized OMRON retail outlet or distributor. • The device should be serviced once a year by an approved OMRON service centre.
  • Page 25: Technical Data

    9. Technical data Name: Comp Air Elite Model: OMRON NE-C30-E Type: Non-heating compressor nebuliser Power Supply: 12VDC 1A (Compressor) 100 - 240VAC, 50/60Hz (AC adapter) Power Consumption: 12 watts ° ° Operating Temperature/ C to +40 C 30% to 85% RH Humidity: °...