Advertisement

PT630D User Reference Guide
unitech Electronic CO. LTD
Unitech
PT630D User Reference Guide
Version 1.1
Unitech Part Number: 400412
1

Advertisement

Table of Contents
loading

Summary of Contents for Unitech PT630D

  • Page 1 PT630D User Reference Guide unitech Electronic CO. LTD Unitech PT630D User Reference Guide Version 1.1 Unitech Part Number: 400412...
  • Page 2: Notice

    PT630D User Reference Guide unitech Electronic CO. LTD NOTICE This unit is equipped with a Li-ion battery pack. Battery power might be low due to storage. Recharge the battery when required. For procedures on 1.5 Quick Start how to charge the battery, please refer to...
  • Page 3: Table Of Contents

    Electronic CO. LTD NOTICE ..............................2 Chapter 1: Introduction..........................4 1.1 Overview ..........................4 1.2 Support..........................4 1.3 Customized PT630D ......................4 1.4 Technical Specification ......................5 1.5 Quick Start..........................6 1. 6 Interface Ports ........................8 1.7 Using the Keyboard....................... 8 1.8 Triggering Scanner Module.....................
  • Page 4: Chapter 1: Introduction

    1.2 Support Over here at unitech, making you satisfy is our first priority. If at anytime, you find any problem regarding to this terminal or any our other product please feel free to contact us at;...
  • Page 5: Technical Specification

    PT630D User Reference Guide unitech Electronic CO. LTD 1.4 Technical Specification Physical Characteristics Dimensions: 165mm x 60mm x 35mm Weight: 230g Drop Specification: 1.2M multiple free drop to concrete floor Display: 128 x 64 pixel; 8 lines, 16 characters per line (small font) or 4 lines, 12 characters (large font).
  • Page 6: Quick Start

    Electronic CO. LTD 1.5 Quick Start This section is designed to let you quickly get familiar with PT630D. If you need detail explanation on some of the functions, please refer to further chapters for detail explanation. PT 630 Illustrations...
  • Page 7 During charging, LED above power icon will be displayed red. Once it is fully charged, LED will be turned to green. 2. Or, use the standard charging cable, which is packed with one of unitech PT630D packages or you can order them separately, together with the power adaptor. Connect the power plug of the adaptor to the charging cable, then, connect the charging cable to the main unit.
  • Page 8: Interface Ports

    Modem/Ethernet Communication 1. 6 Interface Ports PT630D does its’ communication via RS232 communication port located in the back of the unit. You can connect the unit via the communication cable to PC RS232 jack for data transfer or connect through cradle for communication.
  • Page 9: Triggering Scanner Module

    Figure 0-11: PT630D Keypad layout Numeric mode PT630D keyboard is initialized to normal mode after powered on. In normal mode, the cursor is a block and the keyboard is mainly used to input numeric data and use F1-F4 four function-keys.
  • Page 10 PT630D User Reference Guide unitech Electronic CO. LTD Unitech Part Number: 400412...
  • Page 11 For more detailed programming information, please refer to PT630D Programming Reference Manual, JobGen Pro User's Manual. Unitech Part Number: 400412...
  • Page 12: Chapter 2 Power System

    When the main power source is removed or below the level to back-up the RAM and RTC properly, the power circuit of PT630D automatically switches to the Lithium battery for back up. It is recommended that the main battery can be always placed inside the unit with enough capacity for back- up purpose in which case the Lithium battery can supply the power for up to 3 years before consuming all its capacity up.
  • Page 13: Battery Replacement

    PT630D User Reference Guide unitech Electronic CO. LTD 2.3 Battery Replacement Main Battery Make sure the unit is turned off. Turn over the unit; unscrew the battery door lock screw by turning the screw left for quarter turn. Slide the main battery pack from battery compartment.
  • Page 14: Storage And Safety Precautions

    PT630D User Reference Guide unitech Electronic CO. LTD Overcharging may occur when a Li-Ion rechargeable battery is charged in regular or quick charging rate after it has been fully charged, but there is no risk of overcharging while charged in trickle charging rate.
  • Page 15: Chapter 3: Operation

    Supervisor mode is also protected with password checking to prevent unauthorized personnel from changing the system configuration. (For PT630D detail setup procedures p lease refer to PT630D Technical Binder). It is likely that your unit came pre-configure by your software vender or system developer. In this case, please be caution when changing these settings.
  • Page 16: User Mode And System Commands

    PT630D User Reference Guide unitech Electronic CO. LTD 3.2 User Mode and System Commands There are eight system commands: RUN, TER, COM, DIR, ERA, TYP, CPY, and SET. Each command can be invoked through menu-selection in User mode. User can press [CMD] key for two seconds in Ready mode to enter User mode.
  • Page 17: Configure The Terminal In Set Command

    Enable / disable bar code decoding PEN SCAN KEY When pen scanner is used on PT630D, user can setup whether pressing trigger key to enable pen scanner. If ENABLE is selected, user must press and hold down trigger to scan barcode label. If DISABLE is selected, user can directly scan barcode label without pressing trigger key.
  • Page 18: Upload/Download By Esc Command

    “File upload” ESC command. Meanwhile the program running on the host should follow the control flow of MULTI protocol and process to receive the data. For detailed description of each ESC command and protocol, please see the PT630D Programming Reference Manual.
  • Page 19: Chapter 4 Built-In Application: Formcaching

    PT630D User Reference Guide unitech Electronic CO. LTD Chapter 4 Built-in Application: FormCaching The system of terminal includes a built-in application, FormCaching. It allows users to create a data entry application by specifying field prompt, type, length, input method and delimiter, etc. without writing program and loading to the terminal.
  • Page 20: How To Create A Formcaching

    You will need to enter Supervisor mode and select “4.FORM” category in order to set the configuration of FormCaching (refer to the PT630D Programming Reference Manual for how to enter the Supervisor mode). After selecting the “4.FORM” in Supervisor mode, the screen will show as above. The system will first ask user to specify four categories of the field specification including field prompt, data length, data type and device type of each data field.