Page 2
However, PSC reserves the right to change any specification at any time without prior notice. PSC is a registered trademark of PSC Inc. The PSC logo is a trademark of PSC. All other trademarks and trade names referred to herein are property of their respective owners.
Installation Complete the following steps for the appropriate interface. Keyboard Wedge Turn off the terminal or computer. Disconnect the keyboard cable from the back of the terminal or computer. Connect the QS2500 to the terminal or computer using the appropriate interface cable. Turn the terminal or computer back on.
Programming the QS2500 To program the QS2500, you must scan a series of programming bar codes in the correct order. The inside back cover of this manual con- tains a table of alphanumeric bar codes needed to program the various options.
Resetting the QS2500 To return all QS2500 option settings to the factory defaults, scan the fol- lowing three bar codes, in the order shown: Start Program Default Value Initialization Interfaces The QS2500 supports four interfaces, Keyboard Wedge, RS-232, Wand Emulation and USB. The correct interface cable is included for the scan- ner interface type you ordered.
Page 8
Start Program Alphanumeric Option Bar Code Option Entry IBM AT, PS/2 Keyboard Type Reserved 01 - 06 Belgium Keyboard Layout Danish France Germany Italian Portuguese Spanish Swedish Switzerland Latin American Japan 0–8 00–08 (0 = high clock rate; Keyboard Speed 8 = low clock rate) Exit QS2500...
Page 9
When this option is enabled, the QS2500 outputs bar code Function Key: ASCII values from 01 to 1F as function-key presses in your appli- cation. See the table of ASCII codes In Appendix C on page Numeric Key: If your application accepts only keypad numeric code, use setting to make the QS2500 output code as numeric-keypad presses when it reads digits.
PSC Aux. Port: This configures the QS2500 flow control to connect to the Auxiliary (AUX) port of some PSC omni-directional scanners. The QS2500 will assert RTS high to signal the scanner that data will be sent immediately after RTS is asserted. When connecting to a PSC scanner aux.
Page 13
Start Program Alphanumeric Option Bar Code Option Entry None Flow Control RTS/CTS Xon/Xoff ACK/NAK PSC Aux. Port Mode B 00–99 0–99 (msec.) Intercharacter Delay 00–99 0–99 (10 msec.) Block Transmission Delay 00–99 0–99 (100 msec.) Response Delay 300 Baud Baud Rate...
Alphanumeric Option Bar Code Option Entry None Parity Even 8 bits Data Bit 7 bits 1 bit Stop Bit 2 bits Exit a. Reading PDF417 through the Aux. Port is host dependent. Scan Scanning Mode Good-read off: The trigger button must be pressed to activate scan- ning.
Page 15
The QS2500 always keeps a constant reading, and same- Test only: label reading is allowed without double confirmation. The fea- ture can test the performance of the QS2500 for reading speed and sensitivity. Standby Duration: A timeout duration of 1 to 99 seconds can be set. It is effective only when the CCD scanning mode is operated in timeout-off mode and good-read off mode.
Page 16
Alphanumeric Option Bar Code Option Entry 0–99 00–09 (0 = no double con- Double Confirm firm) Disable Multifield Scan Enable Exit Global Minimum/Maximum Code Length: Global minimum and maximum length can be set to qualify data entry. The length is defined as the actual bar code data length to be sent.
Start Program Alphanumeric Option Bar Code Option Entry 00–63 0–63 Global Minimum Code Length 00–63 0–63 Global Maximum Code Length Disable Inverted Image Scan Enable Disable CTS Trigger Enable Disable Visible Scan Field Indicator 30 second 60 second 90 second 120 second 150 second 180 second...
Page 18
After each successful bar code reading, the QS2500 will Beep Control: beep. You can adjust Beep Loudness/Beep-Tone Frequency/Beep-Tone Duration: the loudness, tone, and duration of the good-read beep. Start Program Alphanumeric Option Bar Code Option Entry Disable Power-On Alert Enable Disable LED Indication Enable...
Alphanumeric Option Bar Code Option Entry Disable Beep/Lamp Option 3: Beep & LED after data transmis- Enable sion & CTS active Exit Label Editing (includes Prefix/Suffix) Prefix Characters: Up to 22 ASCII characters may be sent before data. Prefix Data Suffix Suffix Characters: Up to 22 ASCII characters may be sent after data.
Page 20
1. Scan Start Program and Insert G1 Characters Setting bar code below. 2. Use the ASCII code table (see Appendix C on page ) to find the ASCII value for A (41) and B (42). 3. Scan the digit bar codes for 4, 1 and 4, 2 on the inside back cover of this manual.
Page 22
The code ID can be placed before or after the code data. Code ID Position: Start Program Alphanumeric Option Bar Code Option Entry Disable Preamble Transmission Enable Disable Postamble Transmission Enable 0–63 (0 = no insertion) 00–63 Insert Data Group 1 Position 00–ff ASCII code 1–22 characters...
Page 23
This function is used to show unknown bar Code Name Transmission: code symbologies that include all readable symbologies of the QS2500. The code name will be transmitted before the bar code data to identify the symbology. Case Conversion: You can set the alpha characters to be displayed as either uppercase or lowercase.
Symbology Settings UPC-A Read: Format: Leading Zero Data Digits (11 Digits) Check Digit Checksum Transmission: With this option enabled, the QS2500 will trans- mit the checksum. The leading or ending digits of bar code data Truncate Leading/Ending: characters can be truncated. The QS2500 will beep instead of reading anything when the truncate value is more than the bar code data digits or the truncate leading value overlaps the truncate ending value.
Page 25
Start Program Alphanumeric Option Bar Code Option Entry Disable Read Enable Disable Checksum Verification Enable Disable Checksum Transmission Enable 00–15 0–15 Truncate Leading 00–15 0–15 Truncate Ending 00–ff ASCII code 00–ff <A>* Code ID Setting 00–44 0–44 Insertion Group Selection None Supplement Digits 2 digits...
UPC-E Read: Format: Leading Zero Data Digits (6 Digits) Check Digits Checksum Transmission: When this option is enabled, the QS2500 will transmit the checksum. Truncate Leading/Ending: Same as UPC-A. See page Code Id Setting: Same as UPC-A. See page Same as UPC-A. See page Insertion Group Selection: Supplement Digits: Format:...
Page 27
Alphanumeric Option Bar Code Option Entry Disable Checksum Transmission Enable 00–15 0–15 Truncate Leading 00–15 0–15 Truncate Ending 00–ff <E>* 00–ffH ASCII code Code ID Setting 00–44 0–44 Insertion Group Selection None 2 digits Supplement Digits 5 digits UCC/EAN 128 Auto Detection Disable Truncate Leading Zero...
EAN-13 Format Read: Data Digits (12 Digits) Check Digits Checksum Transmission: When this option is enabled, the QS2500 will transmit the checksum. Same as UPC-A. See page Truncate Leading/Ending: Code ID Setting: Same as UPC-A. See page Insertion Group Selection: Same as UPC-A.
Page 29
Alphanumeric Option Bar Code Option Entry Disable Checksum Transmission Enable 00–15 0–15 Truncate Leading 00–15 0–15 Truncate Ending 00–ff <F>* 00–ffH ASCII code Code ID Setting 00–44 0–44 Insertion Group Selection None 2 digits Supplement Digits 5 digits UCC/EAN 128 Auto Detection Disable ISBN/ISSN Conversion...
Page 30
When this option is enabled, the QS2500 will Checksum Transmission: transmit the checksum. Same as UPC-A. See page Truncate Leading/Ending: Code ID Setting: Same as UPC-A. See page Insertion Group Selection: Same as UPC-A. See page Supplement Digits: Format Data Digits (7 Digits) Check Digits Supplement Digits (2 or 5) Truncate Leading Zero:...
Alphanumeric Option Bar Code Option Entry 00–44 0–44 Insertion Group Selection None Supplement Digits 2 digits 5 digits UCC/EAN 128 Auto Detection Disable Truncate Leading Zero Enable Disable Expansion Enable Exit Code 39 Format: Read: Start “*” Data Digits (Variable) Checksum (Optional) End “*”...
Page 32
Each symbology has own maximum and Maximum/Minimum Code Length: minimum code length, which can be set to qualify data entry. The length is defined as the actual bar code data length to be sent. Labels with lengths below the minimum or above the maximum will be rejected.
Interleaved 2 of 5 Format: Read: Data Digits (Variable) Checksum (Optional) Checksum Verification: The checksum is presented as the sum mod 10 of the numerical values of all data digits. When this option is enabled, the QS2500 will Checksum Transmission: transmit the checksum.
Start Program Alphanumeric Option Bar Code Option Entry Disable Read Enable 00–64 0–64 Maximum Code Length 00–64 0–64 Minimum Code Length 00–15 0–15 Truncate Leading 00–15 0–15 Truncate Ending 00–ff ASCII code 00–ff <i>* Code ID Setting 00–44 0–44 Insertion Group Selection Exit Matrix 2 of 5 Read:...
Page 37
When this option is enabled, the QS2500 will Checksum Transmission: transmit the checksum. Same as Code 39. See page Maximum/Minimum Code Length: Truncate Leading/Ending: Same as UPC-A. See page Code ID Setting: Same as UPC-A. See page Insertion Group Selection: Same as UPC-A.
Alphanumeric Option Bar Code Option Entry 00–ff ASCII code 00–ff <B>* Code ID Setting 00–44 0–44 Insertion Group Selection Exit Codabar Read: Format: Start Data Digits (Variable) Checksum (Optional) Checksum Verification: The checksum is presented as the sum mod 16 of the numerical values of all data digits.
Page 39
Start Program Alphanumeric Option Bar Code Option Entry Disable Read Enable Disable Checksum Verification Enable Disable Checksum Transmission Enable 64–00 64–Minimum Maximum Code Length 00–64 0–Maximum Minimum Code Length 00–15 0–15 Truncate Leading 00–15 0–15 Truncate Ending 00–ff ASCII code 00–ff <%>* Code ID Setting...
Alphanumeric Option Bar Code Option Entry Disable Start/End Transmission Enable Exit Code 128 Format: Read: Data Digits (Variable) Checksum (Optional) The checksum is presented as the sum mod 103 of Checksum Verification: all data digits. Checksum Transmission: When this option is enabled, the QS2500 will transmit the checksum.
Page 41
This feature is only used for UCC/EAN-128. The Concatenation Code: Concatenation Code is the separator character, default is <GS> (1D inserted between characters when label data is concatenated and treated as a single entry. For example: • UCC/EAN-128 Structure: <start> <FNC1> <Label data 1> <FNC1> <Label data 2> <CK> <stop>...
Alphanumeric Option Bar Code Option Entry 00–44 0–44 Insertion Group Selection Standard Format UCC/EAN-128 Disable Append Enable 00–ff ASCII code 00–ff <#>* UCC/EAN-128ID Setting 00–ff ASCII code 00–ff Concatenation Code Exit Code 93 Read: Format: Data Digits (Variable) Checksum1 (Optional) Checksum1 (Optional) Checksum Verification: The checksum is presented as the sum mod 47 of...
Code 11 Format: Read: Data Digits Checksum1 Checksum1 (Variable) (Optional) (Optional) The checksum is presented as the sum mod 11 of Checksum Verification: all data digits. Checksum Transmission: When this option is enabled, the QS2500 will transmit one-digit or two-digit checksums, depending upon the setting for checksum verification.
Alphanumeric Option Bar Code Option Entry 00–64 0–Maximum Minimum Code Length 00–15 0–15 Truncate Leading 00–15 0–15 Truncate Ending 00–ff ASCII code 00–ff <O>* Code ID Setting 00–44 0–44 Insertion Group Selection Exit MSI/Plessey Read: Format: Data Digits (Variable) Checksum1 (Optional) Checksum2 (Optional) The MSI/Plessey code has one or two optional Checksum Verification:...
Page 46
Same as UPC-A. See page Insertion Group Selection: Start Program Alphanumeric Option Bar Code Option Entry Disable Read Enable Disable Checksum Verification Mod 10 Mod 10/10 Mod 11/10 Disable Checksum Transmission Enable 64–00 64–Minimum Maximum Code Length 00–64 0–Maximum Minimum Code Length 00–15 0–15 Truncate Leading...
Alphanumeric Option Bar Code Option Entry 00–ff ASCII code 00–ff <@>* Code ID Setting 00–44 0–44 Insertion Group Selection Exit UK/Plessey Format: Read: Data Digits (Variable) Checksum1+2 (Optional) The UK/Plessey code has one or two optional Checksum Verification: checksum digits. The checksums are calculated as the sum mod 10 or 11 of the data digits.
Page 48
Start Program Alphanumeric Option Bar Code Option Entry Disable Read Enable Disable Checksum Verification Enable Disable Checksum Transmission Enable 64–00 64–Minimum Maximum Code Length 00–64 0–Maximum Minimum Code Length 00–15 0–15 Truncate Leading 00–15 0–15 Truncate Ending 00–ff ASCII code 00–ff <@>* Code ID Setting...
Telepen Format: Read: Data Digits Checksum1 (Optional) Checksum Verification: The checksum is presented as the sum mod 10 or 11 of the data digits. Checksum Transmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minimum Code Length: Same as Code 39.
Alphanumeric Option Bar Code Option Entry 00–64 0–Maximum Minimum Code Length 00–15 0–15 Truncate Leading 00–15 0–15 Truncate Ending 00–ff ASCII code 00–ff <S>* Code ID Setting 00–44 0–44 Insertion Group Selection Numeric only Format Full ASCII only Exit Standard 2 of 5 Read: Format Data Digits...
Start Program Alphanumeric Option Bar Code Option Entry Disable Read Enable 00–15 0–15 Truncate Leading 00–15 0–15 Truncate Ending 00–ff ASCII code 00–ff <> Code ID Setting 00–44 0–44 Insertion Group Selection Exit PDF417 Same as UPC-A. See page Truncate leading/ending: Code ID Setting: Same as UPC-A.
Page 60
Matrix 2 of 5 --------- Codabar --------- A 1 1 2 + B Code 128 --------- A 1 2 3 4 5 B c d Code 93 --------- B 6 7 8 9 0 B c d Code 11 --------- MSI/Plessey --------- UK/Plessey...
Appendix D - Parameter Setting List Start Program Standard Parameter Setting List If you wish to display the current configuration of your QS2500 over the host terminal/computer, scan the Bar Code standard parameter setting list bar code. System Parameter Setting List If you wish to display the product information and revision number for your QS2500 over the host terminal/computer, scan the System parameter set- ting list bar code.
Page 67
DECLARATION OF CONFORMITY PSC hereby declares that the Equipment specified below has been tested and found compliant to the following Directives and Standards: Directives: EMC 89/336/EEC Low Voltage 73/23/EEC Standards: CISPR 22-A:1997 - Generic Emissions EN 55022-A:1998 - Generic Emissions...
Page 68
Telephone: [852]-2-584-6210 Telephone: [39] (0) 39/62903.1 Fax: [852]-2-521-0291 Fax: [39] (0) 39/6859496 Australia Japan PSC Asia Pacific Pty Ltd. PSC Japan K.K. North Ryde, Australia Shinagawa-ku, Tokyo, Japan Telephone: [61] 0 (2) 9878 8999 Telephone: 81 (0)3 3491 6761 Fax: [61] 0 (2) 9878 8688...