Bosch UHI Series Operation Manual page 22

Camera housing
Hide thumbs Also See for UHI Series:
Table of Contents

Advertisement

22
en | Connection - Most Models
4
Caution!
Always securely tighten all fittings to ensure a liquid-tight seal. Failure to do so could allow
water to enter the housing and to damage the camera and lens. If a sealant is used, ensure
that it is a neutral cure type. Sealants that release acetic acid may harm camera electronics.
Use of drip loops is recommended on the wiring outside of the rear end cap.
1.
2.
2014.05 | 4.0 | F.01U.167.418
Pull any excess wire out of the housing and tighten the fitting to 8.5 N m to 9.0 N m
(75 in.-lb to 80 in.-lb). This torque rating is approximately one to one and a half turns past
the point where the fitting starts to grip the wire.
Connect the supply power wires to the terminal block. See the figure below. Strip no less
than 6 mm (0.25 in.) and no more than 8 mm (0.31 in.) of insulation away from the wire.
Ensure not to nick the wires.
Cut the power cord on 120 VAC and 230 VAC camera models; leave enough cable to allow
connection to the terminal block. Strip no less than 6 mm (0.25 in.) and no more than
8 mm (0.31 in.) of insulation away from the wire. Ensure not to nick the wires. Connect
these wires to the connectors provided on the terminal block.
Operation Manual