MUZ-FD50
POWER lamp
Abnormal point
(Indoor unit)
(Failure mode / protection)
OFF
None (Normal)
2-time fl ash
Outdoor power system
3-time fl ash
Discharge temperature
thermistor
Defrost thermistor
Ambient temperature
thermistor
Fin temperature thermistor
P.C. board temperature
thermistor
Outdoor heat exchanger
temperature thermistor
4-time fl ash
Overcurrent
5-time fl ash
Discharge temperature
6-time fl ash
High pressure
7-time fl ash
Fin temperature
P.C. board temperature
8-time fl ash
Outdoor fan motor
9-time fl ash
Nonvolatile memory data
10-time fl ash Discharge temperature
11-timefl ash
Communication error between
P.C. boards
Current sensor
Zero cross detecting circuit
Converter
Bus-bar voltage
(1)
Bus-bar voltage
(2)
Even if this protection stop
is performed continuously
3 times, it does not mean
the abnormality in outdoor
power system.
NOTE : Blinking patterns of this mode differ from the ones of Troubleshooting check table (11-3.).
LED indication
(Outdoor P.C. board)
LED1
LED2
Lighting
Lighting Overcurrent protection stop is continuously
performed 3 times within 1 minute after the
compressor gets started, or when converter
protection stop or bus-bar voltage protection
stop is continuously performed 3 times within 3
minutes after start-up.
Lighting
Once
Thermistor shorts or opens during compressor
running.
Lighting
Once
Lighting
Twice
Lighting
3 times
Lighting
4 times
Lighting
9 times
Once
Goes out 28 A current fl ows into intelligent power module. • Reconnect compressor
Lighting
Lighting
Discharge temperature exceeds 116°C during
operation. Compressor can restart if discharge
temperature thermistor reads 100°C or less 3
minutes later.
Lighting
Lighting The outdoor heat exchanger temperature
exceeds 70°C during cooling or the indoor gas
pipe temperature exceeds 70°C during heating.
3 times
Goes out The fi n temperature exceeds 87°C during
operation.
4 times
Goes out The P.C. board temperature exceeds 70°C
during operation.
Lighting
Lighting Failure occurs continuously three times within
30 seconds after the fan gets started.
Lighting
5 times Nonvolatile memory data cannot be read
properly.
Lighting
Lighting The frequency of the compressor is kept 80 Hz
or more and the discharge temperature is kept
under 39°C for more than 20 minutes.
Lighting
6 times Communication error occurs between the
electronic control P.C. board and power board
for more than 10 seconds.
The communication between boards protection
stop is continuously performed twice.
Lighting
7 times A short or open circuit is detected in the current
sensor during compressor operating.
Current sensor protection stop is continuously
performed twice.
5 times
Goes out Zero cross signal cannot be detected while the
compressor is operating.
The protection stop of the zero cross detecting
circuit is continuously performed 10 times.
5 times
Goes out A failure is detected in the operation of the
converter during operation.
5 times
Goes out The bus-bar voltage exceeds 400 V or falls to
200 V or below during compressor operating.
6 times
Goes out The bus-bar voltage exceeds 400 V or falls to 50
V or below during compressor operating.
30
www.ilmalämpöpumput.com
Condition
• Check the connection of the
compressor connecting wire.
• Refer to 11-5.
check inverter/compressor".
• Check the stop valve.
• Refer to 11-5.
outdoor thermistors".
• Replace the outdoor
electronic control P.C. board.
• Refer to 11-5.
outdoor thermistors".
connector.
• Refer to 11-5.
check inverter/compressor.
• Check the stop valve.
• Check refrigerant circuit and
refrigerant amount.
• Refer to 11-5.
LEV".
• Check refrigerant circuit and
refrigerant amount.
• Check the stop valve.
• Check around outdoor unit.
• Check outdoor unit air
passage.
• Refer to 11-5.
outdoor fan motor".
• Refer to 11-5.
outdoor fan motor".
• Replace the outdoor
electronic control P.C. board.
• Check refrigerant circuit and
refrigerant amount.
• Refer to 11-5.
LEV".
• Check the connecting wire
between outdoor electronic
control P.C. board and
power board.
• Replace the power board.
• Check the connecting wire
among electronic control
P.C. board, noise fi lter P.C.
board and power board.
• Replace the power board.