M How to check miswiring and serial signal error
A
Turn OFF inverter-controlled lighting
equipment.
Turn OFF the power supply and then
turn ON again.
Press EMERGENCY OPERATION
switch.
Reinstall
either the unit
or the light
each other
away.
Is serial signal
Attach a fi lter
error indicated 6
No
on remote
minutes later?
control receiv-
Yes
ing section
of the indoor
unit.
B
Turn OFF the power supply.
Is there rated voltage in the
power supply?
Yes
Turn ON the power supply.
Is there rated voltage between outdoor termi-
nal block S1 and S2?
Yes
Press EMERGENCY OPERATION switch once.
Does AREA-L lamp light up? <Confi rmation of
the power to the indoor unit>
Yes
Is serial signal error indicated 6 minutes later?
Yes
A
Turn OFF the power supply.
Check once more if the indoor/outdoor
B
connecting wire is not miswiring.
Short-circuit outdoor terminal block S2
and S3.
1
Turn ON the power supply.
Does the LED on the inverter P.C. board or
the outdoor electronic control P.C. board
repeat "3.6-second-OFF and 0.8-second-
ON quick blinking"?
3
Yes
Turn OFF the power supply.
Remove the short-circuit between
outdoor terminal block S2 and S3.
Turn ON the power supply.
Is there amplitude of 10 to 20 VDC
between outdoor terminal block S2 and
S3? <Confi rmation of serial signal>
Yes
Is there rated voltage between
indoor terminal block S1 and S2?
<Confi rmation of power voltage>
Yes
Replace the indoor electronic control P.C. board.
Be sure to release the failure-mode recall function after checking.
46
www.ilmalämpöpumput.com
Check the power supply.
No
Check the wiring.
No
No
Is there any miswiring, poor
contact, or wire disconnection
of the indoor/outdoor connect-
No
ing wire?
No
1. Miswiring may damage indoor electronic control P.C. board
during the operation.
Be sure to confi rm the wiring is correct before the operation
starts.
3. Be sure to check this within 3 minutes after turning ON. After
3 minutes, LED blinks 6 times. Even when the inverter P.C.
board or the outdoor electronic control P.C. board is normal,
LED blinks 6 times after 3 minutes.
Replace the inverter P.C. board or the
outdoor electronic control P.C. board.
No
2
(Lighted
2. Be careful to the residual voltage of smoothing
or not
capacitor.
lighted)
Is there any error of the in-
door/outdoor connecting wire,
such as the damage of the wire,
No
intermediate connection, poor
contact to the terminal block?
No
Is there any error of the in-
door/outdoor connecting wire,
such as the damage of the wire,
No
intermediate connection, poor
contact to the terminal block?
No
Correct them.
Yes
Replace the indoor/
outdoor connecting
Yes
wire.
Replace the indoor/
outdoor connecting
Yes
wire.