H1/11 RED (+)12V constant power input
Before connecting this wire, remove the supplied fuse. Connect to the positive battery terminal or the constant
12V supply to the ignition switch.
NOTE: Always use a fuse within 12 inches of the point you obtain (+)12V power. Do not use the
15A fuse in the harness for this purpose. This fuse protects the module itself.
H1/12 RED/WHITE channel 2, (-) 200mA output
When the system receives the transmitter code controlling Channel 2 for longer than 1.5 seconds, the red/white
wire will supply an output as long as the transmission continues. This is often used to operate a trunk/hatch
release or other relay-driven functions.
IMPORTANT! Never use this wire to drive anything but a relay or a low-current input! The transis-
torized output can only supply 200 mA of current. Connecting directly to a solenoid, motor, or other
high-current device will cause it to fail.

plug-in LED and valet/program switch

The LED and the Valet/Program switch both plug into the control module. The status LED plugs into the white
two-pin port, while the Valet
Valet
®
/Program switch each fit into
© 2001 Directed Electronics, Inc. Vista, CA
®
/Program switch should be plugged into the blue two-pin port. The status LED and
/
-inch holes.