Haier AB242ACBEA Service Manual page 92

Commercial air conditioning 24 28 universal outdoor unit air conditioning
Hide thumbs Also See for AB242ACBEA:
Table of Contents

Advertisement

2. Heating
begining
fails in heating
condensate
flowage failure
airiness circle
improperly
blowing cold air
prevent cold air
failure
the enactment TEMP.
right or not
N
the heating load
beyond the allowable
arange
fault in 4-way vavle
N
quantity of condensate
charge is not enough
N
Y
compressor fault
Y
fan speed at
low-speed
N
air entrance filter
obstruct
heat insulation of condensate
pipeline between indoor unit
and outdoor unit is normal
fault in 4-way vavle
pipe sensor of
indoor unit is fault
Figure
7-2
-51-
Y
change the designed
TEMP.
Y
use arange is right
or not
Y
change the
4-way vavle
Y
superaddition condensate
replacing compressor
enact fan speed of
high or middle speed
Y
clear the filter
Y
insulate the two
pipeline respective
Y
replacing the
4-way vavle
Y
replacing the
4-way vavle
Y
redesign the TEMP.