Confirmation Of Parts; Specifications; Product Specifications; External View - Mitsubishi Electric PAC-YG63MCA Instruction Manual

Air conditioner network system
Hide thumbs Also See for PAC-YG63MCA:
Table of Contents

Advertisement

3

Confirmation of Parts

• Confirm that the box contains the following parts.
Number
1
2
* In addition to the parts mentioned above, other parts need to be procured locally in order to operate this device. Furthermore, other Mitsubishi optional
parts may be required depending on how the device is to be used.
For details, refer to "6 Installation Method".
4

Specifications

4-1. Product Specifications

Item
Power Supply
24 VDC±10%: 5 W
M-NET communication
Ch1
Interface
Ch2
(*2)
Interlock
Interlock M-NET devices according to measurement data values. (*4)
Function
Temperature
Environment
Conditions
Humidity
Dimensions
200 (W) × 120 (H) × 45 (D) mm / 7
Weight
0.6 kg / 1 3/8 lb
Current Time
If the power is cut, an internal capacitor will normally keep counting the current time for approximately one week.
Power Failure
(The internal capacitor takes approximately a day to charge. Replacement of a battery is not necessary.)
Backup
Installation
Inside a control panel (indoors)
Environment
* Use this product in a hotel, a business office environment or similar environment.
*1: Supply electric power from a power supply unit for the transmission line or an outdoor unit. Furthermore, the power consumption factor of the M-NET
circuitry of this unit is "1/4" (equivalent to one ME Remote Controller).
*2: Configure the dip switch settings for the analog input method to use while referring to "9 Switch List".
*3: The measurement error for the system includes the measurement error for this unit, sensor, and wiring.
*4: Settings for the interlock function are performed from the maintenance tool. For details, refer to the instruction manual for the Maintenance Tool.

4-2. External View

Installation/instruction manual (this document)
17 to 30 VDC (*1)
Measurement
Ch
Sensor
Pt100
Temperature
(3-wire system)
4 to 20 mADC
Temperature/
1 to 5 VDC
0 to 10 VDC
4 to 20 mADC
Temperature/
1 to 5 VDC
0 to 10 VDC
Upper/lower limit
alarm output
(non-voltage contact)
Operating temperature range
Storage temperature range
30 to 90%RH (no condensation)
This device complies with Part15 of the FCC Rules.Operation is
subject to the following two conditions: (1)this device may not cause
harmful interference, and (2)this device must accept any interference
received, including interference that may cause undesired operation.
26
(
1
1
/
32
Part Name
AI controller
Description
Measurement
target
range
-30 to 60°C
[-22 to 140°F]
(Set by system
humidity
controller)
(Set by system
humidity
controller)
Applied load
MAX: 24 VDC, 5 W
MIN: 5 VDC, 2 mW
* AC loads cannot be connected.
7
/
(W) × 4
3
/
(H) × 1
25
/
(D) in
8
4
32
/
46
(
1
13
)
16
200
(
7
/
)
7
8
/
150
(
5
29
)
32
4.5
(
3
/
16
Al controller
PAC-YG63MCA
[ OUTPUT ] Non-voltage Contact Output
Ch1
Ch2
Alarm
Alarm
[ Output LEDs ]
Ch1
Ch2
Alarm
Alarm
N623
Al controller
MODEL
PAC-YG63MCA
SERVICE REF. PAC-
YG60MCA-J
INPUT
VOLTAGE
DC24V;0.2A
WEIGHT
0.6 kg / 1 /
3 8
lb
SERIAL No.
MADE IN JAPAN
[ INPUT ]
[ 24 VDC Power Supply]
Ch1
Ch2
Pt100
4 to 20 mA / 1 to 5 V / 0 to 10 V
4 to 20 mA / 1 to 5 V / 0 to 10 V
)
/
83.5
(
3
5
/
)
27
(
1
3
)
32
16
2
Measurement error
±0.3%FS ±0.1°C (0.18°F) (*3)
[at 25°C (77°F)]
±0.5%FS ±0.1°C (0.18°F) (*3)
±0.5%FS ±0.1%RH
[at 25°C (77°F)]
±0.5%FS ±0.1°C (0.18°F) (*3)
±0.5%FS ±0.1%RH
[at 25°C (77°F)]
0 to 40°C [32°F to 104°F]
-20 to 60°C [-4°F to 140°F]
45
(
1
25
/
)
32
9
(
3
/
)
8
)
Quantity
1
1
Screw terminal
block (M3)
Screw terminal
block (M3)
External connection
method
Screwless terminal
block (3 poles)
Screwless terminal
block (2 poles)
Screwless terminal
block (2 poles)
Screw terminal
block (M3.5)
Unit: mm (in)