EverFocus ED350 Operation Instructions Manual

EverFocus ED350 Operation Instructions Manual

1/3” 560 tvl color mini dome camera
Hide thumbs Also See for ED350:

Advertisement

Quick Links

Please read this manual first for correct installation and operation. This manual should be retained
for future reference. The information in this manual was current when published. The
manufacturer reserves the right to revise and improve its products. All specifications are therefore
subject to change without notice.
PRECAUTIONS
1.
Do not install the camera near electric or magnetic fields.
Install the camera away from TV, radio transmitter, magnet, electric motor, transformer,
audio speakers since the magnetic fields generate from above devices will distort the video
images.
2.
Never disassemble the camera nor put impurities in it.
Disassembly or impurities may result in trouble or fire.
3.
Never face the camera toward the sun.
Direct sunlight or severe ray may cause fatal damage to sensor and internal circuit.
4.
Keep the power cord away from water and liquid.
Touching the wet power cord may result in electric shock.
5.
Never install the camera in areas exposed to water, oil or gas.
Water, oil or gas may result in failure, electric shock or fire.
6.
Cleaning
Do not touch the surface of sensor by hand directly. Use a soft cloth to remove the dirt from
the camera body. Use lens tissue or a cotton swab and ethanol to clean the sensor and the
camera lens.
1/3" 560 TVL Color Mini Dome Camera
EVERFOCUS
Operation Instructions
ED350
Model No.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ED350 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EverFocus ED350

  • Page 1 EVERFOCUS 1/3” 560 TVL Color Mini Dome Camera Operation Instructions ED350 Model No. Please read this manual first for correct installation and operation. This manual should be retained for future reference. The information in this manual was current when published. The manufacturer reserves the right to revise and improve its products.
  • Page 2: Package Contents

    LEVEL volume control for the best viewing quality. ED300 is 520TVL dome camera equipped with simple Day and Night feature. ED350 is 560TVL high resolution. ED230/330 is day and night IR Dome camera.
  • Page 3: Optional Accessories

    OPTIONAL ACCESSORIES • BA-ED- Mounting L-Bracket for ED Series Mini Dome Cameras • EN220 5.6-inch LCD Test Monitor...
  • Page 4: Specifications

    SPECIFICATIONS Pickup Device 1/3'' SONY Super HAD CCD Video Format NTSC or PAL NTSC: 525 TV lines, 60 fields/sec Scanning System PAL: 625 TV lines, 50 fields/sec Picture Elements 768 x 494(NTSC) ; 752 x 582(PAL) Horizontal Resolution 560TVL Sensitivity 0.5Lux/F=1.2 S/N Ratio Over 48dB(AGC off)
  • Page 5 DIMENSIONS...
  • Page 6 (1) Camera Cover This cover will protect the camera from dust and damage. (2) Lens ED350 and ED300 come with vari-focal lens. ED200, ED230/330 comes with fixed lens. This Vari-Focal Lens allows users to adjust the Zoom and Focus manually. (3) Base The camera unit is set in the dome base when it is shipped from the factory.
  • Page 7 To set the focus, loosen the Focus ring knob first, then turn the ring toward <∞> or <N> as necessary. When the focus is obtained as desired, tighten the focus ring knob. (5) Zoom Ring Loosen the zoom ring knob, then you can adjust the viewing range. Turn the ring towards <W> for WIDE or <T>...
  • Page 8: Installation

    INSTALLATION This section cover simple steps and detail installation. Please follow instruction for preventing any unnecessary damage. Simple Steps: 1. Open Camera Cover 2. Mount Camera on Ceiling 3. Connect power, video 4. Optional Connect to EN220 Test Monitor for field testing (monitor is not included) 5.
  • Page 9 4. Optional Connect to EN220 Test Monitor for field testing (monitor is not included) It is highly recommend to use Everfocus Test Monitor to test the camera. Find the Video testing connector as following. Connect it to testing monitor for field testing.
  • Page 10: Zoom And Focus Adjustments

    5. Zoom and focus adjustments After the camera was installed, the zoom and focus of the lens must be adjusted. 1. Loosen the zoom ring knob, and then turn the ring towards <W> or <T> as necessary to obtain the desired view range.
  • Page 11: Camera Setting

    Camera Setting NOTE: Be very careful not to scratch or damage the lens while making any kind of setting Audio (Optional) (1) IRIS ALC Adjustment To select light metering method: Turn the IRIS ALC Adjustment VR counterclockwise for Average Metering. Turn the IRIS ALC Adjustment VR clockwise for Peak Metering.
  • Page 12 (3) Flickerless When picture flicker fiercely, turn FL on, then the camera will stabilize the speed of electronic shutter at 1/100(NTSC) or 1/120(PAL) automatically, and reduce the flicker immediately. The default setting is OFF. (4) Auto Gain Control Adjustment AGC ON: The sensitivity increases automatically when the light is low. AGC OFF: A low-noise picture is obtained under a low light condition.
  • Page 13: Everfocus Electronics Corp

    FAX: 631-436-5027 TEL: +81-43-212-8188 www.everfocus.com FAX: +81-43-297-0081 www.everfocus.com Your EverFocus product is designed and Ihr EverFocus Produkt wurde entwickelt und manufactured with high quality materials and hergestellt mit qualitativ hochwertigen components which can be recycled and Materialien und Komponenten, die recycelt reused.

Table of Contents