ATTACHING THE AIR PURIFYING FILTERS
CAUTION
Cleaning and maintenance must be carried out only by qualiÀ ed service personal. Before cleaning,
stop operation and switch off the power supply.
1
Open the front panel.
●
Pull up the front panel by holding it at both sides with
both hands.
2
Remove the pre-À lters.
●
Push upward to release the claws and pull out the
pre-À lters.
3
Attaching the air purifying À lters to the pre-À lter.
●
Attach the air purifying À lters to the frame by gently
compress its both sides and release after insertion
into À lter frame.
Do not bend the air purifying À lter as
it may cause damage to the structure.
Please do not smell direct from source
of À lter.
4
Attach the pre-À lters.
●
Attach the pre-À lters by ensuring that the surface
written "FRONT" is facing front.
●
After attaching the pre-À lters, push the front panel at
three arrow portion as shown in À gure and close it.
NOTE
●
In case of removing the air purifying À lters, please follow the above procedures.
●
The cooling capacity is slightly weakened and the cooling speed becomes slower when the air purifying À lters are
used. So, set the fan speed to "HIGH" when using it in this condition.
●
Air purifying À lters are not washable. It is recommended to use vacuum cleaner to clean it. It can be use for 1 year
time. Type number for this air purifying À lter is <SPX-CFH22>. Please use this number for ordering when you want
to renew it.
●
Do not operate the air conditioner without pre-À lter. Dust may enter the air conditioner and fault may occur.
CAUTION
Claws
Claws
(4 places)
(4 places)
– 20 –