4-2-3.Measuring Intrument And Jig Connection Diagram; 4-2-4.Environmental Settings - FujiFilm FinePix6800Zoom Service Manual

U/e/eg_model
Hide thumbs Also See for FinePix6800Zoom:
Table of Contents

Advertisement

4.Adjustment and Check
4-2-3.Measuring Instrument and Jig Connection Diagram
FinePix6800Zoom
(note1)Please sence input voltage at DC_IN terminal in case of System block adjustment.

4-2-4.Environmental Settings

(1)Environmental Setting for Image System Adjustment(Fig.A)
<<Full White Pattern>>
Remove the chart from the pattern box. Position the
camera (lens surface when the power is on) and pattern
box so that they are separated by approximately 5 cm.
Arrange so that the standards for the pattern box are as
follows.
1. Brightness: 160+-5 cd/m
No chart - Center of pattern box.
Minolta luminous meter LS-110
2. Color warmth: 6100+-50
No chart - Center of pattern box.
Minolta colormeter F
(2)Environmental Setting for Flash Adjustment/Inspection(Fig.B)
The strobe adjustment is easily affected by other
sources of light. Make the area around the gray chart
extremely dark to minimize the affects of other sources
of light.
Position 100 cm from the camera (lens surface).
Gray chart standards
Gray chart should be Superior Oxford Gray (No. 22) and
a material with a reflection ratio of 18+-0.7%.
(3)Environmental Setting for AF Adjustment(Fig.C)
1.The distance from the camera to the AF chart is set with
conversion lenses of the f=600mm or 900mm as shown in
a right picture.
2.The AF chart is shone on by using the source of light.
Please give brightness on the surface of the AF chart as
9.0-12.0Ev.
3.Please set the lens position of the camera on the concen-
tric circle about the conversion lens.
16
USB Terminal
DC_IN Terminal
Power Cable Jig
Digital Voltmeter
(note1)
Digital Voltmeter
(note1)
2
(with LB140 filter)
o
K (with LB140 filter)
FinePix6800Zoom(U/E/EG) SERVIS GUIDE
Personal Computer
USB Cable
DC5V
Reguratted power supply
Reguratted power supply
Li BATT Jig
50+-5
camera
Body
Filter(LB140)
Fig.A
100cm
camera
Body
Fig.B
30+-5mm
o
When the f=600mm close-up lens is used
During INF,600mm adjustment
200mm adjustment
o
When the f=900mm close-up lens is used
During INFadjustment920+-5mm
600mm adjustment
200mm adjustment
Fig.C
DC5V
mm
Pattern
BOX
Gray chart
Fluorenscent
Light Stand
AF Chart
620+-5mm
220+-5mm
620+-5mm
220+-5mm

Advertisement

Table of Contents
loading

Table of Contents