Showline SL WASH 350 RGBW Owenrs Manual

Led luminaire
Table of Contents

Advertisement

Quick Links

SL WASH 350 RGBW LED Luminaire

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SL WASH 350 RGBW and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Showline SL WASH 350 RGBW

  • Page 1 SL WASH 350 RGBW LED Luminaire...
  • Page 2: Showline Offices

    Information contained in this document may not be duplicated in full or in part by any person without prior written approval of Showline. Its sole purpose is to provide the user with conceptual information on the equipment mentioned. The use of this document for all other purposes is specifically prohibited.
  • Page 3: Important Information

    Showline Limited Two-Year Warranty Showline offers a two-year limited warranty of its luminaires against defects in materials or workmanship from the date of delivery. A copy of Showline two-year limited warranty containing specific terms and conditions can be obtained by contacting your local Showline office.
  • Page 4: Table Of Contents

    INSTALLATION AND SET UP Power Requirements ................................... 7 AC Power Operation................................7 Connecting Power..................................8 Connecting SL WASH 350 RGBW LED Luminaires to AC Power.................. 8 Connecting to the DMX512 Network............................9 Mounting Luminaire ................................. 10 OPERATION AND PROGRAMMING LCD Display and Menu System ............................... 11 LCD Display and Menu System Operation ..........................
  • Page 5 Installation & User’s Manual HSIC Mode ....................................31 HSIC Group Modes .................................. 32 SL WASH 350 RGBW LED Luminaire DMX Timing Channel Detail................... 33 SL WASH 350 RGBW LED Luminaire RDM Parameter IDs....................39 CLEANING AND CARE Special Cleaning and Care Instructions ............................ 43 Front Lens Cleaning..................................
  • Page 6: Preface

    Please read all instructions before installing or using this product. Retain this manual for future reference. Additional product information and descriptions may be found on the product specification sheet. Note: The SL WASH 350 RGBW LED Luminaire is universal voltage 100 to 240 VAC (auto-ranging). 2. Included Items...
  • Page 7: Sl Wash 350 Rgbw Led Luminaire Overview

    Luminaire Base LCD Display / Menu System DMX512 / RDM Input DMX512 / RDM Output AC Output AC Input Bottom of Base Figure 2: SL WASH 350 RGBW LED Luminaire Components Sh wline SL WASH 350 RGBW LED Luminaire Components...
  • Page 8: Lcd Display / Menu System

    (with rotation of menu) Figure 3: LCD Display & Menu System Note: For Menu operation and programming details, refer to "LCD Display and Menu System" on page Sh wline SL WASH 350 RGBW LED LUMINAIRE OVERVIEW...
  • Page 9: Installation And Set Up

    INSTALLATION AND SET UP 1. Power Requirements The SL WASH 350 RGBW LED Luminaire operates on AC input voltages from 100 to 240 VAC. WARNING! This unit does not contain an ON/OFF switch. Always disconnect power input cable to completely remove power from unit when not in use.
  • Page 10: Connecting Power

    Table 2 on page 8 describes how to connect power to your SL WASH 350 RGBW LED Luminaire. Field wiring of the SL WASH 350 RGBW LED Luminaire is straight forward. A total of 3 wires/conductors is supplied from the unit.
  • Page 11: Connecting To The Dmx512 Network

    DMX connector on the first SL WASH 350 RGBW LED Luminaire. Another cable runs from the other DMX connector on the first unit to a DMX connector on the next SL WASH 350 RGBW LED Luminaire (or DMX512 device to be controlled).
  • Page 12: Mounting Luminaire

    4. Mounting Luminaire SL WASH 350 RGBW LED Luminaires are provided with the ability to hang via truss hooks, clamps, etc. (sold separately) or floor mounted (sitting on fixture base). Securely attach a hook, clamp, etc. to each Omega Mount (two supplied with unit).
  • Page 13: Operation And Programming

    Installation & User’s Manual OPERATION AND PROGRAMMING 1. LCD Display and Menu System The SL WASH 350 RGBW LED Luminaire’s LCD Display and Menu System provides local control for accessing the following fixture’s settings: • Presets (Standard and User Defined) •...
  • Page 14: Sl Wash 350 Rgbw Led Luminaire Main Menu Options

    Figure 8: LCD Display and Menu System 3. SL WASH 350 RGBW LED Luminaire Main Menu Options Presets Presets are stored values of the luminaire's LED settings that can be recalled via the menu system or DMX. You can customize up to 31 presets via the menu system.
  • Page 15: Color Filter

    Delete the currently selected step in the Edit Step field. Press the Check Mark button to Delete Step delete the current step. Rainbow Press the Check Mark button to display the Rainbow Chase editor. Sh wline SL WASH 350 RGBW LED Luminaire Main Menu Options...
  • Page 16: Edit Rainbow

    SL WASH 350 RGBW LED Luminaire Installation & User’s Manual To edit and save a Step: Step 1. Select Edit Step or New Step from the Edit User Chase menu. Step 2. The top left field indicates the preset or color filter to be used for the step. When set to OFF no preset or color filter is to be used.
  • Page 17: Settings/Security

    The time used to change color values when running a chase. Settings/Security All Showline fixtures have a multiple level locking feature. This allows you to configure the fixture and allow different menu access to multiple users. The menu system can be locked instantly or assigned to power on to a particular lock level.
  • Page 18: Settings/General

    SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Settings/General Use the Up and Down buttons to select parameters and the Left and Right buttons to assign the different general fixture settings. When finished, press the Check button to exit the menu level. The adjustable parameters are described in Table 9.
  • Page 19: Settings/Dmx Control Channel

    Note: When the fixture is powered off, the Lock Fixture function will be disabled. To assign fixture power-up security refer to (see "Settings/Security" on page 15 for more information). Sh wline SL WASH 350 RGBW LED Luminaire Main Menu Options...
  • Page 20: Password (Passpin)

    • Press the Check Mark button to exit the Status screen. Quick Selection Buttons The Showline menu system includes four quick selection buttons on the top of the menu. These keys provide direct access to common functions and act as shortcuts to main menu items as described in Table 13.
  • Page 21: Harmonize Color Calibration

    When enabled either via DMX or the fixture's menu, the Harmonize technology will ensure that colors match from fixture-to-fixture and pixel-to- pixel. As the Harmonize system matches Showline products, they will all operate in the same color space. Use the Harmonize system when perfect color matching is an essential requirement.
  • Page 22: Master / Slave Operational Mode

    6. Master / Slave Operational Mode The Master / Slave Operational Mode allows one SL WASH 350 RGBW LED Luminaire to act as the "Master" unit and all other connected units are controlled by this unit. When a unit is set to "Slave" mode, it will only listen to and follow any commands sent from a "Master"...
  • Page 23: Dmx Control

    1 function and other functions follow in sequence. 1. 16-Bit Mode Table 15 provides DMX channel mapping of all DMX512 control values when the SL WASH 350 RGBW LED Luminaire is in 16-bit DMX512 mode (as set by the luminaire’s menu system).
  • Page 24 SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 15: DMX Channel Mapping (16-Bit Mode) CONTINUED FROM PREVIOUS PAGE CF_0_Color OFF DMX 69 - 70 CF_1_White 10000K DMX 71 - 72 CF_2_White 8000K DMX 73 - 74 CF_3_White 6500K DMX 75 - 76...
  • Page 25 SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 15: DMX Channel Mapping (16-Bit Mode) Controls strobe operations as follows: Open = DMX 0 - 2 Closed = DMX 3 - 5 Slow Rand = DMX 6 - 7...
  • Page 26: 16-Bit Group Modes

    Installation & User’s Manual 2. 16-Bit Group Modes Table 16 provides DMX channel mapping of all DMX512 control values when the SL WASH 350 RGBW LED Luminaire is operated in various 16-bit DMX512 Group Control Modes. Table 16: DMX Channel Mapping (16-Bit Group Modes)
  • Page 27: 8-Bit Rgbw Mode

    Installation & User’s Manual 3. 8-Bit RGBW Mode Table 17 provides DMX channel mapping of all DMX512 control values when the SL WASH 350 RGBW LED Luminaire is in 8-bit DMX512 mode (as set by the luminaire’s menu system). Table 17: DMX Channel Mapping (8-Bit RGBW Mode)
  • Page 28 SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 17: DMX Channel Mapping (8-Bit RGBW Mode) CONTINUED FROM PREVIOUS PAGE CF_0_Color OFF DMX 69 - 70 CF_1_White 10000K DMX 71 - 72 CF_2_White 8000K DMX 73 - 74...
  • Page 29 SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 17: DMX Channel Mapping (8-Bit RGBW Mode) Controls strobe operations as follows: Open = DMX 0 - 2 Closed = DMX 3 - 5 Slow Rand = DMX 6 - 7...
  • Page 30: 8-Bit Rgbw Group Modes

    Installation & User’s Manual 4. 8-Bit RGBW Group Modes Table 18 provides DMX channel mapping of all DMX512 control values when the SL WASH 350 RGBW LED Luminaire is operated in various 8-bit DMX512 Group Control Modes. Table 18: DMX Channel Mapping (8-Bit Group Modes)
  • Page 31: Simple Rgbw 8-Bit Mode

    Installation & User’s Manual 5. Simple RGBW 8-Bit Mode Table 19 provides DMX channel mapping of all DMX512 control values when the SL WASH 350 RGBW LED Luminaire is in Simple RGBW 8-bit DMX512 mode (as set by the luminaire’s menu system).
  • Page 32: Simple Rgbw 8-Bit Group Modes

    Installation & User’s Manual 6. Simple RGBW 8-Bit Group Modes Table 16 provides DMX channel mapping of all DMX512 control values when the SL WASH 350 RGBW LED Luminaire is operated in various Simple RGBW 8-bit DMX512 Group Control Modes.
  • Page 33: Hsic Mode

    Installation & User’s Manual 7. HSIC Mode Table 21 provides DMX channel mapping of all DMX512 control values when the SL WASH 350 RGBW LED Luminaire is in HSIC (Hue, Saturation, Intensity, and Color Correction) DMX512 mode (as set by the luminaire’s menu system).
  • Page 34: Hsic Group Modes

    Installation & User’s Manual 8. HSIC Group Modes Table 22 provides DMX channel mapping of all DMX512 control values when the SL WASH 350 RGBW LED Luminaire is operated in various HSIC DMX512 Group Control Modes. Table 22: DMX Channel Mapping (HSIC Group Modes)
  • Page 35: Sl Wash 350 Rgbw Led Luminaire Dmx Timing Channel Detail

    9. SL WASH 350 RGBW LED Luminaire DMX Timing Channel Detail Timing channel control improves the timed moves of certain groups of parameters. The SL WASH 350 RGBW LED Luminaire provides timing channels in 16-bit mode (one for intensity time and one for color time) and one timing channel in 8-bit (color and intensity timing combined).
  • Page 36 SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 23: SL WASH 350 RGBW LED Luminaire Timing Channel Detail = Seconds % Value (unless noted) 10.2 10.4 10.6 10.8 11.2 11.4 11.6 11.8 12.2 12.4 12.6 12.8 13.2 13.4...
  • Page 37 SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 23: SL WASH 350 RGBW LED Luminaire Timing Channel Detail = Seconds % Value (unless noted) 16.6 16.8 17.2 17.4 17.6 17.8 18.2 18.4 18.6 18.8 19.2 19.4 19.6 19.8...
  • Page 38 SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 23: SL WASH 350 RGBW LED Luminaire Timing Channel Detail = Seconds % Value (unless noted) Sh wline DMX CONTROL...
  • Page 39 SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 23: SL WASH 350 RGBW LED Luminaire Timing Channel Detail = Seconds % Value (unless noted) Sh wline SL WASH 350 RGBW LED Luminaire DMX Timing Channel Detail...
  • Page 40 SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 23: SL WASH 350 RGBW LED Luminaire Timing Channel Detail = Seconds % Value (unless noted) 5 Minutes 15 Minutes 30 Minutes 60 Minutes 250* 60mS 251* 80mS 252*...
  • Page 41: Sl Wash 350 Rgbw Led Luminaire Rdm Parameter Ids

    • Table 27, “RDM Manufacturer Status IDs,” on page 41 • Table 28, “RDM Manufacturer Specific PIDs for Root Device,” on page 42 • Table 29, “SL WASH 350 RGBW LED Luminaire RDM Manufacturer Specific PIDs for Sub Device,” on page 42 Table 24: RDM Product Parameters IDs...
  • Page 42 SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Table 26: RDM Parameters IDs RDM Parameter IDs Value Comment Implemented Allowed Allowed Category - Network Management ■ DISC_UNIQUE_BRANCH 0x0001 ■ DISC_MUTE 0x0002 ■ DISC_UN_MUTE 0x0003 ■ PROXIED_DEVICES 0x0010 ■...
  • Page 43 Manufacturer ID. See Table B-2, ANSI E1.20- 2010. Status ID Message Value Data Value 1 Data Value 2 Status ID Description 8100H ALL OK Sh wline SL WASH 350 RGBW LED Luminaire RDM Parameter IDs...
  • Page 44 8A44H None None Setup ■ ■ 8A41H None None Lock Fixture Table 29: SL WASH 350 RGBW LED Luminaire RDM Manufacturer Specific PIDs for Sub Device Type Length Unit Prefix Default Description Allowed Allowed Parameter IDs Category - Manufacturer Defined PIDs - Range is 0x8000-0xffdf (See ANSI E1.20-2010 Standard, Table A-3) ■...
  • Page 45: Cleaning And Care

    SL WASH 350 RGBW LED Luminaire. These types of cleaners or solvents can permanently damage the optics or housings of the fixture. If you have any questions regarding the use or care of your SL WASH 350 RGBW LED Luminaire, please contact Showline technical support or your local Authorized Dealer.
  • Page 46: Technical Specifications

    SL WASH 350 RGBW LED Luminaire Installation & User’s Manual TECHNICAL SPECIFICATIONS 1. SL WASH 350 RGBW LED Luminaire Operational Specifications Source: RGBW LED Array (19) Beam Angle: 8 to 40 Degrees Light Output: > 5,800 lumens / CRI/CQS: > 90 (RGBW)
  • Page 47 SL WASH 350 RGBW LED Luminaire Installation & User’s Manual Notes Sh wline SL WASH 350 RGBW LED Luminaire Dimensions...

This manual is also suitable for:

350

Table of Contents