Outdoor model
Function
Power supply
Capacity
Dehumidification
w
Air flow(High/Low )
Power outlet
Running current
Power input
Power factor
Starting current
Compressor motor current
Fan motor current
Coefficient of performance(C.O.P)
Model
Output
Winding
resistance(at 20:)
Model
Winding
resistance(at 20:)
Dimensions WOHOD
Weight
Sound level(High/Low )
Fan speed(High/Low )
Fan speed regulator
Refrigerant filling
capacity(R410A)
Refrigerating oil (Model)
Thermistor RT62(at 25:)
Thermistor RT63(at 0:)
NOTE: Test conditions are based on JIS C 9612.
Cooling : Indoor
Outdoor DB35°C WB(24°C)
Indoor-Outdoor piping length : 5m
w Reference value
kW
R/h
K /h
A
A
W
%
A
A
A
W
"
"
mm
kg
w
dB
w
rpm
kg
cc
k"
k"
DB27°C WB19°C
MU-A30WV -
Cooling
Single phase
230V, 50Hz
8.5
4.6
2,940/1,470
25
14.42
3,191
96
90
13.85
0.57
2.61
NN37VAAHT
2,500
C-R 0.64
C-S 1.63
RA6V75-AB
WHT-BLK 62.8
BLK-YLW 55.9
YLW-RED 26.0
840o850o330
75
w
55/53
805/435
2
2.30
1,300 (NEO 22)
231.44
33.18
6
E1
w