Exhaust Emissions Information (Gasoline) - Generac Power Systems 005411-0 Owner's Manual

Air-cooled recreational vehicle generators rv 45, 55 and 65
Table of Contents

Advertisement

1.6.3
GENERATOR SPECIFICATIONS
SERIES
Rotor RPM
Rotor Poles
Engine RPM
Rated Max. Continuous AC Output Watts*
Voltage*
Rated Max. Continuous Current Amps (240V)
Phase
Frequency
Weight
Length
Width
Height
* All units are re-connectable to 120 and/or 240 volts, dual voltage output. Units are not listed per RVIA/ANSI when reconnected for dual voltage output
** Maximum wattage and current are subject to, and limited by, such factors as fuel Btu content, ambient temperature, altitude, engine condition, etc.. Maximum power
decreases about 3.5% for each 1,000 feet above sea level; and will also decrease about 1% for each 6° C (10° F) above 16° C (60° F) ambient temperature.
1.6.4
ENGINE SPECIFICATIONS
Type of Engine ........................................................................GT-530
Cooling Method ................................................................ Air-cooled
Rated Horsepower ...................................................18 at 3600 rpm
Displacement ........................................................................... 530cc
Compression Ratio ................................................................8.5 to 1
Cylinder Block .................................. Aluminum w/Cast Iron Sleeve
Type of Governor .......................................Electronic, Fixed Speed
Engine Governor Speed ................................................... 2571 rpm
Air Cleaner ................................................................. Paper Element
Starter .................................................................. 12-volt DC Electric
Ignition System ............................ Solid-state w/Flywheel Magneto
Recommended Spark Plug
NGK ....................................................................................BPR6HS
Spark Plug Gap ............................................. 0.030 inch (0.76 mm)
Recommended Min. Battery .................. 400 Cold Cranking Amps
Class II Emission Certified
1.7
EXHAUST EMISSIONS
INFORMATION (GASOLINE)
The Environmental Protection Agency (EPA) and the California Air
Resource Board (CARB) require that this generator comply with
exhaust emission standards. The generator is certified to meet all
applicable exhaust emission levels. This generator is certified for
use as a mobile engine. It is important that you follow the mainte-
nance specifications listed in this manual to ensure that the engine
complies with emission standards for the duration of its life. This
engine is certified to operate on gasoline. The emission control
system on the generator consists of the following:
RV45G
3600
2
2571
4500
120
37.5 (18.7)
1
60 Hertz
278 lbs.
33.7 in.
21.5 in.
16.8 in.
Fuel Metering System
~ Carburetor assembly
~ Fuel pump and lines
Air Induction System
~ Intake pipe / manifold
~ Air cleaner
Ignition System
~ Spark plug
~ Ignition module
Catalytic Converter (if equipped)
The Emissions Compliance Period referred to on the Emissions
Compliance Label indicates the number of operating hours for
which the engine has been shown to meet Federal and California
emission requirements. See the table below to determine the com-
pliance period for this generator. The displacement of the engine is
listed on the Emissions Compliance Label.
Displacement
> 66 cc - < 225 cc
≥ 225 cc
General Information
RV55G
3600
2
2571
5500
120
45.8 (22.9)
1
60 Hertz
285 lbs.
33.7 in.
21.5 in.
16.8 in.
Category
Compliance Period
A
B
C
A
B
C
RV65G
3600
2
2571
6500
120
54.1 (27)
1
60 Hertz
293 lbs.
33.7 in.
21.5 in.
16.8 in.
500 Hours
250 Hours
125 HOurs
1000 Hours
500 Hours
250 Hours
7

Hide quick links:

Advertisement

Table of Contents
loading