IC701 RH-iX0400AWZZ: System Microcomputer (IX0400AW) (1/2)
Pin No.
Port Name
1
AVDD
AVDD
2
ANI0
SPEANA AOUT
3
ANI1
CAM A SW A
CAM A SW B
4
ANI2
CAM A SW C
CAM A SW D
5
ANI3
CAM A SW E
CAM B SW A
6
ANI4
CAM B SW B
TRAY SW A
7
ANI5
TRAY SW B
TRAY SW C
8
ANI6
KEY 0
9
ANI7
KEY 1
10
ANI8
KEY 2
11
ANI9
T1RUN
12
ANI10
T2RUN
13*
ANI11
TUN SM
SPN
14
AVSS
AVSS
15
VSS1
VSS1
16
X1
X1
17
X2
X2
18
VDD1
VDD1
19
IC(VPP)
IC(VPP)
20
T100
REMOCON
21
P25
CD DO
22
P26
CD DI
23
P27
CD CLK
24
P67
CD CE
25
P66
WRQ
26
INTP1
SP DET
27
INTP0
P IN
28
P63
CE O
29
P62
CLK
30
P61
DI
31
P60
DO
32
P57
TIMER LED
33
P56
T SOL A
34
P55
T SOL B
35
P54
T MOTOR
36
P53
MICOM RESET
37
P52
PLAY SW B
38
P51
FPA
39*
P50
FPB
40
VSS0
VSS0
41
VDD0
VDD0
42
RESET
RESET
43
P47
RESOUT
44*
P46
RDS RST/HSS ACK
45*
P45
RDS RDDA/HSS STB
46*
P44
RDS RDCL/HSS DI
In this unit, the terminal with asterisk mark (*) is (open) terminal which is not connected to the outside.
Terminal Name
Input/Output
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Input
Output
Input
Input
Input
Output
Output
Output
Input
Input
Input
Output
Output
Output
Input
Output
Output
Output
Output
Input
Input
Input
Input
Input
Output
Output
Input
Output
ANALOG VDD
SPEANA INPUT
CD CAM A SW A CONTROL
CD CAM A SW B CONTROL
CD CAM A SW C CONTROL
CD CAM A SW D CONTROL
CD CAM A SW E CONTROL
CD CAM B SW A CONTROL
CD CAM B SW B CONTROL
CD TRAY SW A
CD TRAY SW B
CD TRAY SW C
KEY INPUT
KEY INPUT
KEY INPUT
TAPE 1 RUN PULSE INPUT
TAPE 2 RUN PULSE INPUT
TUNER SIGNAL METER
TUNER SPAN SELECT
ANALOG GND
GND
MAIN CLOCK
MAIN CLOCK
(+) POWER SUPPLY
OPEN
REMOTE CONTROL INPUT
CD DSP CODE O OUT
CD DSP COMMAND
CD DSP CLOCK
CD DSP CE
CD DSP WRITE REQUEST
CD RF LEVEL DETECTION
SYSTEM STOP INPUT
CE OUTPUT
CLOCK OUTPUT
DATA OUTPUT
DATA INPUT
TIMER LED CONTROL
TAPE 1 SOLENOID CONTROL
TAPE 2 SOLENOID CONTROL
TAPE MOTOR CONTROL
MICROCOMPUTER RESET
PLAY SWITCH FOR TAPE 2
TAPE 2 A-SIDE FULL PROOF
TAPE 2 B-SIDE FULL PROOF
GND
(+) POWER SUPPLY
RESET
CD DSP RESET
RAM RESET/ESS SYS ACKNOL
RANSMIT DATA INPUT/ESS STB
RDS CLOCK/ESS DATA OUTPUT
– 55 –
CD-BA3100
Function

Hide quick links: