46
10
47
When the height of
STB holder is low,
(Increase the clearance.)
Bend this part.
Scale: 2 magnifications
42
LIFT GEAR A
45
11
When the height of
STB holder is high,
(Decrease the clearance.)
240
OS LEVER
Bend this part to adjust the height of the STB holder.
Details
41
43
STB HOLDER HEIGHT ADJUSTING METHOD
Adjusting procedure
1. Turn the mode big gear approx. 37 degrees in the arrow direction.
2. Viewing from the front side of the mechanism, verify that the guide ribs
(CHANGE BOX L/R and STB HOLDER) of tray are as tall as each other.
3. If they are not, bend the lever for adjustment. (Refer to the details.)
Note: Also apply the same adjustment on the R side.
Height of the rib
Figure 21
– 21 –
CD-BA3100
80
TOP PLATE F
37°
Mark position
32
33
30
35
40
44
80
TOP PLATE F
40
30
35