B.1.2 Shield Termination Technique – Method A.1 (Standard)
For the following steps please refer to the drawings showing the installation of a
Jackscrew Backshell.
1. The appropriate number of Jackscrew Backshells will be included in the particular LRU connector kit.
Table B-3 Shielded Cable Preparations for Garmin Connectors
Number
Back-
of Pins
shell Size
Std/HD
1
9/15
2
15/26
3
25/44
4
37/62
5
50/78
2. At one end of a shielded cable (item 2) measure a distance between "Window Min" to "Window Max"
(Table B-3) and cut a window (max size 0.35") in the jacket to expose the shield (Figure B-2). Use
caution when cutting the jacket to avoid damaging the individual braids of the shield. When dealing
with a densely populated connector with many cables, it may prove beneficial to stagger the windows
throughout the "Window Min" to "Window Max" range. If staggering is not needed the "Ideal
Window" length is recommended.
Suggested tools to accomplish the window cut:
• Coaxial Cable Stripper
• Thermal Stripper
• Sharp Razor Blade
GDU 37X Installation Manual
190-01054-01
NOTE
Figure B-2 Method A.1 for Shield Termination
Float Min
Float Max
(inches)
(inches)
1.25
2.25
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
Window
Ideal Float
Min
(inches)
(inches)
1.75
2.75
2.0
3.0
2.0
3.0
2.0
3.0
2.0
3.0
Window
Ideal
Max
Window
(inches)
(inches)
5.25
4.25
5.5
4.5
5.5
4.5
5.5
4.5
5.5
4.5
Page B-3