DeLonghi DGS 61 ST User Operating Instructions Manual page 19

Table of Contents

Advertisement

LOC TION
The appliance may be installed in a kitchen, Kitchen/diner or a bed sitting room, but
not in a room or space containing a bath or a shower.
– The appliance must not be installed in a bed-sitting room of less than 20 m 3 .
– The appliance is designed and approved for domestic use only and should not be
installed in a commercial, semi commercial or communal environment.
– Your product will not be guaranteed if installed in any of the above environments
and could affect any third party or public liability insurances you may have.
PROVISION FOR VENTIL TION
The appliance should be installed into a room or space with an air supply in accor-

dance with BS 5440-2: 2000.

For rooms with a volume of less than 5 m
free area will be required.

For rooms with a volume of between 5 m
2
50 cm
free area will be required unless the room has a door which opens direct-
ly to the outside air in which case no permanent ventilation is required.

For rooms with a volume greater than 10 m
NB. Regardless of room size, all rooms containing the appliance must have
direct access to the outside air via an openable window or equivalent.

Where there are other fuel burning appliances in the same room, BS 5440-2: 2000
should be consulted to determine the correct amount of free area ventilation require-
ments.

The above requirements allow also for use of a gas oven and grill but if there are
other gas burning appliances in the same room, consult a qualified engineer.
3
- permanent ventilation of 100 cm
3
3
and 10 m
a permanent ventilation of
3
- no permanent ventilation is required.
2
19