Problem
Air Hammer will
1. Not enough air pressure and/
not start
2. Obstructed trigger.
3. Incorrect lubrication or not
4. Blocked air inlet screen (if
5. Air leaking from loose housing.
6. Mechanism contaminated.
7. Vane wear or damage.
Housing heats
1. Incorrect lubrication or not
during use.
2. Worn parts.
Severe air
1. Cross-threaded housing
leakage.
(Slight air leakage
is normal,
2. Loose housing.
especially on older
tools.)
3. Damaged valve or housing.
4. Dirty, worn or damaged valve.
Follow all safety precautions whenever diagnosing or servicing the
tool. Disconnect air supply before service.
PLEASE READ THE FOLLOWING CAREFULLY
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY
DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR
DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT
HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS
QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/
OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD
BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE
BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE
ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER
INSTALLATION OF REPLACEMENT PARTS THERETO.
SKU 98672

Troubleshooting

Possible Causes
or air flow.
enough lubrication.
equipped).
enough lubrication.
components.
For technical questions, please call 1-800-444-3353.
Likely Solutions
1. Check for loose connections and make sure
that air supply is providing enough air flow
(CFM) at required pressure (PSI) to the
tool's air inlet. Do not exceed maximum air
pressure.
2. Clean around trigger to ensure free
movement.
3. Lubricate using air tool oil and grease
according to directions.
4. Clean air inlet screen of buildup.
5. Make sure housing is properly assembled
and tight.
6. Have qualified technician clean and lubricate
mechanism. Install in-line filter in air supply
as stated in Initial Set Up: Air Supply.
7. Replace all vanes.
1. Lubricate using air tool oil and grease
according to directions.
2. Have qualified technician inspect internal
mechanism and replace parts as needed.
1. Check for incorrect alignment and uneven
gaps. If cross-threaded, disassemble and
replace damaged parts before use.
2. Tighten housing assembly. If housing cannot
tighten properly, internal parts may be
misaligned.
3. Replace damaged components.
4. Clean or replace valve assembly.