Maintenance And Servicing; Troubleshooting - Central Pneumatic 97014 Set Up And Operating Instructions Manual

Engine cleaning gun with siphon hose
Table of Contents

Advertisement

8.
You can adjust the amount of engine cleaning solution being used by turning the
Siphon Control Knob (6) counterclockwise for more solution and clockwise for
less. See Figure 1 on page 6.
9.
Hold the end of the Spray Nozzle (4) approximately 6 to 10 inches from the
engine and squeeze the Knurled Knob Trigger (5).
10.
It is best to keep the Gun in motion with a back and forth action.
11.
When the job is completed, flush the Siphon Hose (2) by placing it into a
container filled with clean, clear water and spraying it in a safe direction until
only clean water comes from the Spray Nozzle (4).
12.
To prevent accidents, disconnect the air supply after use and store the tool
indoors out of children's reach.
warning
warning
1.
BeFore each use, inspect the general condition of the tool. Check for
loose hose connections, cracked hoses, inoperative trigger and siphon control,
cracked or broken parts, and any other condition that may affect its safe
operation.
2.
aFter use, clean external surfaces of the tool with clean, moist cloth.
problem
Tool has low air
output
SKU 97014

Maintenance and serVicing

Before performing any inspection, maintenance, or
cleaning procedures, disconnect the air supply.
damaged equipment can fail, causing serious personal
injury. do not use damaged equipment. if anything
abnormal occurs, have the problem corrected before
further use.
cleaning, maintenance, and lubrication

troubleshooting

possible causes
1.
Broken hoses, loose connections
2.
Air regulator not set at proper PSI
3.
Siphon Control Knob in a closed
position
For technical questions, please call 1-800-444-3353.
probable solutions
1.
Check all hoses for leaks
and connections. Replace if
necessary.
2.
Check, make sure Air Regulator is
set at 60 PSI
3.
Open the Siphon Valve