Installation Location; Installing The Indoor Unit - Mitsubishi Electric PCA-RP-KAQ Installation Manual

Pca-rp•kaq series air-conditioners
Hide thumbs Also See for PCA-RP-KAQ:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

2. Installation location

Fig. 2-1

3. Installing the indoor unit

Fig. 3-1
A
2
B
75
233
246
Fig. 3-2
2.1. Outline dimensions (Indoor unit) (Fig. 2-1)
(mm)
Select a proper position allowing the following clearances for installation and main-
tenance.
Mount the indoor unit on a ceiling strong enough to withstand the weight of
the unit.
2.2. Outline dimensions (Outdoor unit)
Refer to the outdoor unit installation manual.
3.1. Check the indoor unit accessories (Fig. 3-1)
The indoor unit should be supplied with the following accessories
(contained in the inside of the intake grille).
3.2. Preparation for installation (Fig. 3-2)
(mm)
236
3.2.1. Suspension bolt installing spacing
3.2.2. Refrigerant and drain tubing location
2
85
86 2
138
In case of the rear pipe arrangement, make sure to remove the shaded portions
from the
position.
(The heat exchanger might be clogged because of dust)
C
D
233
246
Models
W
RP50
960
RP60,71
1280
RP100 ,125,140
1600
Warning:
Accessory name
Washer
4 pcs
Pipe cover
1 pc Large size (For gas tubing)
Pipe cover
1 pc Small size (For liquid tubing)
Band
4 pcs
Joint socket
1 pc Marked with "UNIT"
Socket cover
1 pc
Drain tubing cover
1 pc
Flare nut
1 pc ø6.35 (RP60 only)
Models
A
RP50
917
RP60,71
1237
RP100,125 ,140
1557
Models
C
RP50
184
RP60
179
RP71-140
180
Front side outlet
Left side outlet
Right side outlet
Independent piece (Removable)
Right drain tubing
independent piece. Then put the
Q'ty
(mm)
B
960
1280
1600
(mm)
D
203
203
200
Left drain tubing
Gas tubing
Liquid tubing
Rubber plug
with Joint socket
independent piece back in initial
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents