Operation

Reset

Default Values

Whites Setting

White Calibration

-12-
This setting enables the user to reset the COLORado™ Ridge IP to the default values,
including the custom programs.
1. Go to SET.
2. Select REST.
3. When PASS shows, press <SET>.
4. Enter the master access password as shown in Control Panel Lock.
5. Wait for the reset process to finish. (REST will strobe momentarily.)
6. The display will show END.
Parameter
STAT
AUTO
ADDR
RUN
PERS
DIM
This setting enables the user to select and edit the temperature of the white colors used in
channel 12 (Macros) when in the TOUR mode. It also enables the user to define the
maximum RGB values when RGB to White (RGB.W) is active.
1. Go to CAL1.
2. Select a white color (WHITE 1~11).
3. Select a color (RED, GREN, BLUE, WHIT, or AMBE).
4. Select a color value (0~255).
5. Repeat for the other colors.
This setting enables the user to select the white color shown by the COLORado™ Ridge IP
when the color setting is RGBW and the DMX controller's Red, Green, and Blue faders are
set to "255."
1. Go to CAL2.
2. Select a color (RED, GREN, or, BLUE).
3. Select a color value (0~255).
4. Repeat for the other colors
When selecting CAL2 > RGBW you will only be able to define the values of RED,
GREN (green), and BLUE.
The values of RED, GREN, and BLUE configured from CAL2 > RGBW will define the
color temperature shown when the RGB faders are set to "255" if SET > COLO >
RGBW is active.
Default Value
Parameter
R/G/B/W/A/S 000
COLO
AT.01
EDIT
D.001
CAL1
DMX
RGB.W
TOUR
WDMX
DIM4
Default Value
UC
PR.01/SC.01
WH.01
R/G/B.255
ACTI
COLORado™ Ridge IP User Manual Rev. 8