Figure 30. Normal flame pattern.

Fireplace Operation

1. The GI 450 DV Katahdin gas insert is equipped with
an On/Off/T-stat rocker switch to control burner
functions. Use the T-stat position for use with an
optional wall-mounted thermostat. Separate
switches are provided for the multifunction forced
air blower kit.
2. When lit for the first time, the Katahdin will emit an
odor for several hours. This odor is the burn-off by-
products of external paints and lubricants used in
the manufacturing process. Open a nearby window
to provide fresh air and alleviate this temporary
condition.
3. Condensation may occur on the glass upon each
lighting of the appliance. This "fog" will disappear as
the appliance temperature increases.
4. Keep the controls and the area under the appliance
free of debris; vacuum this area frequently. Always
keep the appliance area clear and free from combus-
tible materials, gasoline and other flammable
liquids. ALWAYS be sure the insert is cold and NO hot
embers or sparks are present before using a vacuum
cleaner.
5. Remember, this appliance has a continuous burning
pilot flame. Exercise caution when using products
with combustible vapors.
6. CAUTION: DO NOT OPERATE THIS APPLIANCE WITH
THE GLASS REMOVED, CRACKED OR BROKEN. RE-
PLACEMENT OF THE GLASS SHOULD BE DONE BY A
LICENSED OR QUALIFIED SERVICE PERSON. USE ONLY
REPLACEMENT GLASS PROVIDED BY YOUR AUTHO-
RIZED JØTUL DEALER. NEVER USE ANY SUBSTITUTE
MATERIALS.
WARNING:
OBSERVE CAUTION NEAR THE DOOR. THE GLASS
PANEL MAY SHATTER UNEXPECTEDLY IF STRUCK
WITH AN OBJECT. ALWAYS HANDLE THE GLASS
PANEL WITH CARE.
20
7. Clean the glass only when necessary. Wipe surface
with a clean, dampened, soft cloth. Follow with a dry,
soft towel as desired. Take care not to scratch the
glass surface.
WARNING:
DO NOT USE ABRASIVE CLEANERS ON THE
GLASS. NEVER CLEAN THE GLASS WHEN IT
IS HOT.

Maintenance

The Katahdin gas insert and its venting system should
be inspected before use and at least annually by a
qualified service technician.
IMPORTANT:
ALWAYS TURN OFF THE GAS SUPPLY TO THE
INSERT AND UNPLUG THE FORCED AIR BLOWER
BEFORE ANY SERVICE WORK IS PERFORMED ON
THE INSERT.
General cleaning: The firebox should be vacuumed out
annually to remove any surface build up. Be sure to
vacuum or wipe off the pilot assembly and burner
orifice and burner tube. Also, when vacuuming the
log set, be sure to handle it carefully as it is very
fragile.
Gasket inspection: It is important that the glass gasket
be inspected at least annually. Examine the rope
gasket for signs of deterioration and make sure the
gasket has a positive seal. This is important to
prevent combustion gases from escaping into the
room. Replace the gasket if necessary, refer to the
replacement parts list on page 23.
To remove the glass panel or glass gasket:
1. Open the bottom grill assembly.
2. Release the glass clips on either side of the bottom of
the firebox.
3. Swing the bottom of the glass frame out and lift
slightly.
4. Remove the glass panel by lifting the glass frame
over the brackets at the upper grill assembly.NOTE:
IT IS NOT NECESSARY TO REMOVE THE UPPER GRILL
ASSEMBLY.
5. Lay the assembly on a flat surface and lift the metal
tabs that secure the glass panel to the frame.
6. Install the new glass panel and gasket in the glass
frame and secure with metal tabs. Do not over
tighten tabs as this could break the glass.
ALWAYS USE JØTUL AUTHORIZED PARTS. NEVER
SUBSTITUTE ANY OTHER PARTS.