G
W
G
W
POWER
W
SUPPLY
BK
BK
W
MANUAL OFF AUTO
Figure 19. Blower Wiring Diagram - GI 450 Katahdin

Wall Thermostat

When installing a wall mounted thermostat to the
Katahdin, it must be a 750 millivolt DC two-wire circuit
thermostat. The thermostat should be placed in the
same room as the heater, typically 5' off the floor. Avoid
drafty areas or any area that may affect the accuracy of
the thermostat.
The thermostat should be connected to the
Katahdin using a minimum of 16 gauge wire with a
maximum length of 35 feet of wire.
Connect the two thermostat wire leads to the two
lower terminals on the terminal block located to the
right of the ON/OFF/TSTAT switch. Do not overtighten
the connections. IT IS NOT NECESSARY TO DISCONNECT
ANY OTHER WIRES. See Figure 20.
For the thermostat to function, the ON/OFF/T-STAT
switch must be in the T-STAT position, and the pilot
light must be running, as it is the power source for the
thermostat.
At the thermostat, the two wires should be con-
nected to the two connections screws on the thermo-
stat base plate per the manufacturer's instructions.
THERMOPILE
TH
TP
TH
TP
VALVE
Figure 20. Wiring diagram / GI450 DV Katahdin
M
BLOWER
W
BK
W
R
SNAP STAT
W
R
LO OFF HI
W
W
SWITCH
ROCKER
SWITCH
ON
OFF
STAT
OPTIONAL
THERMOSTAT
REMOTE
CONTROL
TERMINAL
BLOCK

Optional Remote Control

#129706
The optional Jøtul remote can be installed on the
Katahdin gas insert. Using the wires supplied with
the remote, it is best to wire the remote directly to
the gas control valve of the insert.
Connect one receiver lead to the terminal
labelled TH. Connect the other receiver lead to the
terminal labeled TH/TP. DO NOT DISCONNECT ANY
OTHER WIRES FROM THE VALVE, AND DO NOT OVER
TIGHTEN TERMINAL SCREWS.
Jøtul recommends the use of the optional
Remote Receiver Heat Shield (# 129708) to protect
the receiver under the firebox. The best location for
the receiver is just below the air intake port toward
the back of the unit.
Figure 21. Remote Receiver position.
LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING THE CONTROLS.
WIRING ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION. ALWAYS VERIFY
PROPER OPERATION AFTER SERVICING THE
APPLIANCE.
AU MOMENT DE L'ENTRETIENDES
COMMANDES, ETIQUETEZ TOUS LES FILS
or
AVANT LE DEBRANCHEMENT. DES ERREURS
DE CABLAGE PEUVENT ENTRAIUN
FONCTIONNEMENT INADEQUAT ET
DAGEREUX.
Place Receiver Here
CAUTION:
ATTENTION:
Air Intake
Port