Fault Isolation Codes - Rinnai RHFE-551FA Service Manual

Direct vent fireplace
Hide thumbs Also See for RHFE-551FA:
Table of Contents

Advertisement

Fault Isolation Codes

Analog
Digital
Indicator
LED
Light
LO-HI
PF --
Power Failure
:--
60
11
Missed Ignition Flame rod current
LO
12
68
14
Overheat Safety
HI
16
72 76
31
Disconnection
76 80
32
thermistor short
8
Name
Electric power has
been lost while the
appliance was running
does not reach 1.0
microamp within a
certain time after the
solenoid opens.
Flame Failure
Flame rod current
remains below 1.0
microamp for 3
seconds during initial
combustion
High limit temperature
Device
thermistor or thermal
fuse has activated
Over
Room temperature is
Temperature
above 104ºF for
Cut Off
longer than 10
minutes
Room
Room temperature
Temperature
thermistor circuit is
Thermistor
open
Room
Room temperature
temperature
thermistor wire is
trapped or touching
circuit
bare metal.
Rinnai Direct Vent Service Manual
Definition
Check that the power cord is firmly inserted into
the electrical outlet.
Check the 3 amp fuse.
Check whether the fuse or breaker has blown at
the switch board.
Check that the flame rod is firmly positioned.
Check the flame rod lead.
Check the flame rod for carbon build up.
Check that the correct gas is being used.
Check the supply pressure at the meter and at
the appliance.
Check that there are no leaks in the gas supply
line or appliance.
Check for air in the gas supply.
Check that the correct gas is being used.
Check the supply pressure at the meter and at
the appliance.
Check that there are no leaks in the gas supply
line or appliance.
Check for air in the gas supply.
Check that the correct gas is being used.
Check the supply pressure at the meter and at
the appliance.
Check that the flue terminal is not blocked.
Check that the air filter is not blocked.
Check that the warm air flow is not blocked.
(There should be a clearance of 40 inches in front
of the appliance.)
Check that the correct gas is being used.
Check the supply pressure at the meter and at
the appliance.
Check that the flue terminal is not blocked.
Check that the air filter is not blocked.
Check that the warm air flow is not blocked.
(There should be a clearance of 40 inches in front
of the appliance.)
Check the circuit. (troubleshooting)
Check the circuit. (troubleshooting)
Corrective Action