Specification - Mitsubishi Electric City Multi PEFY-P30NMHU-E-F Technical & Service Manual

Series pefy ceiling concealed (fresh air intake type) multiple split type air-conditioners
Hide thumbs Also See for City Multi PEFY-P30NMHU-E-F:
Table of Contents

Advertisement

SPECIFICATION

3
3-1. Specification
PEFY-P-NMHU-E-F
Item
Power sourse
Cooling
Capacity
*1
Heating
Height
Dimension
Width
Depth
Net weight
Airflow rate
FAN
External static
pressure *3
Noise level *2
Filter
Notes: *1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.
Cooling: Indoor: 33 ˚C [91
Heating: Indoor: 0
*2 The operating noise is the data that was obtained in an anechoic room.
*3 As for the factory setting is below.
PEFY-P-NMHU-E-F series
PEFY-P30NMHU-E-F
208V
85
a). The cooling and heating capacities are the maximum capacities that were obtained by operating in the above air conditions
and with a refrigerant pipe of about 7.5m.
b). The actual capacity characteristics vary with the combination of indoor and outdoor units. See the technical information.
c). The operating noise is the data that was obtained by measuring it 1.5m from the bottom of the unit in an anechoic room.
(Noise meter A-scale value)
d). The figures of Electrical characteristic of P30 and P54 models indicate at middle external static pressure,
electrical characteristic of P72 and P96 models indicate at high external static pressure.
e). When the 100% fresh air indoor units are connected, the maximum connectable indoor units to 1 outdoor unit are as follows.
Heat pump models
110%(100% in case of heating below-5˚C)
f ). Operational temp range is cooling : from 21˚C[70˚F]DB/15.5˚C[60˚F] WB to 43˚C[109˚F]DB/35˚C[95˚F]WB.
✻Thermo off (Fan) operation automatically starts either when temperature is lower than 21˚CDB in cooling mode or when
the temperature exceeds 20˚C[68˚F]DB in heating mode.
g ). As the room temp is sensed by the thermo in the remote controller or the one in the room, be sure to use ether remote
controller or room thermo.
h ). Dry mode is Not available. Fan mode operation during the thermo off in Cooling/Heating mode.
i ). The fan would temporarily stops either with R2/WR2 system or in defrost.
j ). In any case, the air flow rate should be kept lower than 110% of the above chart.Please see " Fan curves " for the details.
k ). When this unit is used as sole A/C system, be careful about the dew in air outlet grilles in cooling mode.
l ). Un-conditioned outdoor air such as humid air or cold air blows to the indoor during thermo off operation.
Please be careful when positioning indoor unit air outlet grilles, ie take the necessary precautions for cold air, and also
insulate rooms for dew condensation prevention as required.
m). Air filter must be installed in the air intake side.The filter should be attached where easy maintenance is possible in case of
usage of field supply filters.
n ). Long life filter cannot be used with Hi-efficiency filter together.
Model
kW
BTU/h
kW
BTU/h
mm
in
mm
in
mm
in
kg
lb
3
m
/min
cfm
208V
Pa
230V
208V
dB(A)
230V
˚
F] DB/28
˚
C [82
˚
F] WB
˚
C [32
˚
F] DB/-2. 9
˚
C [27
˚
F] WB
PEFY-P54NMHU-E-F
230V
208V
130
85
Heating : from -10˚C[14˚F]DB to 20˚C[68˚F]DB
PEFY-P30NMHU-E-F
PEFY-P54NMHU-E-F
8.8
30000
54000
8.4
28500
51000
380
14-31/32
1000
39-3/8
47-1/4
900
35-7/16
50
111
9
318
35-85-170
35-85-170
50-130-210
60-130-220
38
43
Outdoor: 33
˚
C [91
Outdoor: 0
˚
C [32
PEFY-P72NMHU-E-F
230V
208V
130
180
Cooling only
110%
PEFY-P72NMHU-E-F
208/230V, 60Hz
15.8
21.1
72000
14.9
19.9
68000
1200
70
155
18
28
636
989
180
260
38
43
43
47
Standard filter
˚
F] DB
˚
F] DB/- 2.9
˚
C [27
˚
F] WB
PEFY-P96NMHU-E-F
230V
208V
260
180
PEFY-P96NMHU-E-F
28.1
96000
26.4
90000
470
18-17/32
1250
49-7/32
1120
44-1/8
100
221
35
1236
180
260
44
48
230V
260
6