OPERATING PROCEDURE
(3) After removing the fixing screws (H) (as shown models
30, 54) of the front fan case (B) and remove the fan.
Pull the fan case (B).
(4) Remove the fixing screws (K) (three) of the bell mouse (J)
attached fan case (L), and remove the bell mouse (J).
(Fig.12)
(5) Remove the fixing screws (four) of the motor base(D).
Notice: It's necessary using the driver over 30cm length to
remove the fixing screws (a) .
(Fixing screws are placed back)(Fig. 13)
(6) Slide the motor (M) with motor base (D) in direction of arrow
2 . (Fig. 14)
Notice: It's not necessary removing the fan case (L).
Fig.14
21
(M)
Arrow
2
Fig.11
(B)
Fig.12
(J)
Fig.13
Fixing screws (a)
Fig.15
(D)
Be careful on removing heavy parts.
PHOTOS
Fixing screws (H)
(D)
(L)
Fixing screws (K)
Fixing screws
Motor base(D)
Motor (M)