Vertical Through-The-Roof; Applications & Installation - Monessen Hearth WDV Wideview WDV500 Installation And Operating Instructions For

Wdv wideview direct vent gas fireplace
Table of Contents

Advertisement

WDV Series Gas Fireplace
Foundation
Recess
Watertight Seal
Around Pipe
Figure 17 -
Snorkel Installation, Recessed Foundation
FP1966
Do not back fill around snorkel.
snorkel
a clearance of at least 4" must be
maintained between the snorkel and
the soil.
VertIcal (thrOuGh-the-rOOF)
applIcatIOns
This gas fireplace has been approved for,
Vertical installations up to 40' (1 m) in height. Up to
a 10' (3 m) horizontal vent run can be installed within
the vent system using a maximum of two 90° elbows.
Figure 18
nOte: Horizontal and vertical sections of this vent system
require a minimum 1" clearance to combustibles at the top,
sides and bottom.
40' Maximum Height
1' Minimum Height
1" Min.
FP1183
Figure 18 -
Support Straps for Horizontal Runs
16
FP1183
Snorkel
Wall Screws
Sheet Metal
Screws
10'
Maximum
Support Straps
Every 3'
Up to two 45° elbows may be used within the horizontal
run. For each 45° elbow used on the horizontal plane,
the maximum horizontal length must be reduced by 18"
(450 mm).
Example: Maximum horizontal length
No elbows = 10' (3 m)
1x45° elbows = 8.5' (.6 m)
x45° elbows = 7' (.1 m)
A minimum of an 1' (3.6 m) vertical rise is
required.
Two sets of 45° elbows offsets may be used within
the vertical sections. From 0 to a maximum of 8'
(.5 m) of vent pipe can be used between elbows.
Figure 19
The maximum angular variation allowed in the
system is 70°. Figure 19
Example:
Total Angular Variation =
1
2
3
4
1" Min.
Figure 19 -
Maximum Elbow Usage
VentInG InstallatIOn
Elbow 1 =
Elbow  =
Elbow 3 =
Elbow 4 =
FP1179
78D0011
90°
45°
45°
90°
70°
1
2
3
4