Monessen Hearth WDV Wideview WDV500 Installation And Operating Instructions Manual

Monessen Hearth WDV Wideview WDV500 Installation And Operating Instructions Manual

Direct vent gas fireplace
Table of Contents

Advertisement

WDV Wideview
Direct Vent Gas Fireplace
Model: WDV500
Installation and Operating
Instructions
WarnInGs
IF the InFOrMatIOn In these InstructIOns
are nOt FOllOWeD exactly, a FIre
Or explOsIOn May result causInG
prOperty DaMaGe, persOnal Injury Or
lOss OF lIFe.
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
What tO DO IF yOu sMell Gas
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
WarnInG: Improper installation, adjustment,
alteration, services or maintenance can cause
injury or property damage. refer to this manual.
For assistance or additional information
consult a qualified installer, service agency or
the gas supplier.
this appliance may be installed in an aftermarket*,
permanently located, manufactured home (usa
only) or mobile home, where not prohibited by local
codes.
this appliance is only for use with the type(s) of
gas indicated on the rating plate unless a certified
kit is used.
*aftermarket: completion of sale, not for purpose of resale, form
the manufacturer.
WarnInG
Due tO hIGh teMperatures, the applIance
shOulD Be lOcateD Out OF traFFIc anD
aWay FrOM FurnIture anD DraperIes.
chIlDren anD aDults shOulD Be alerteD
tO the haZarDs OF hIGh surFace
teMperature anD shOulD stay aWay tO
aVOID Burns Or clOthInG IGnItIOn.
yOunG chIlDren shOulD Be superVIseD
When they are In the saMe rOOM as the
applIance.
clOthInG Or Other FlaMMaBle MaterIal
shOulD nOt Be placeD On Or near the
applIance.
Keep the rOOM area clear anD Free
FrOM cOMBustIBle MaterIals, GasOlIne,
anD Other FlaMMaBle VapOrs anD
lIquIDs.
Installer: leave this manual with the appliance.
cOnsuMer: retain this manual for future refer-
ence.
780012
DVW/WDV cover
78D0011 7/09 Rev. 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WDV Wideview WDV500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Monessen Hearth WDV Wideview WDV500

  • Page 1 WDV Wideview Direct Vent Gas Fireplace Model: WDV500 Installation and Operating Instructions WarnInGs IF the InFOrMatIOn In these InstructIOns are nOt FOllOWeD exactly, a FIre Or explOsIOn May result causInG prOperty DaMaGe, persOnal Injury Or lOss OF lIFe. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Table Of Contents

    WDV Series Gas Fireplace thank you and congratulations on your purchase of a please reaD the InstallatIOn anD OperatIOn InstructIOns BeFOre usInG the applIance! IMpOrtant: read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Important safety Information ...3 code approval ...4 product Features ...5...
  • Page 3: Important Safety Information

    IMpOrtant saFety InFOrMatIOn Installer Please leave these instructions with the appliance. • read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. • any change to this fireplace or its controls can be dangerous. •...
  • Page 4: Code Approval

    WDV Series Gas Fireplace 14. Do not use any solid fuels (wood, coal, paper, card- board, etc.) in this fireplace. Use only the gas type indicated on rating plate. 15. This appliance, when installed, must be electrically grounded in accordance with local codes or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
  • Page 5: Product Features

    prODuct Features and cODe apprOVal prODuct specIFIcatIOns • This appliance has been certified for use with either natural or propane gas. See appropriate data plates. • This appliance is not for use with solid fuels. • The appliance is approved for bedroom or bedsitting room installations.
  • Page 6: Fireplace & Framing Dimensions

    WDV Series Gas Fireplace 57 ” (1470 mm) Figure 2 - Fireplace and Framing Dimensions Do not fill spaces around firebox with insulation or other materials. this could cause a fire. unit framing is to be rectangular front to back. Failure to do so will cause fire and damage to property.
  • Page 7: Fireplace Location

    pre-InstallatIOn InFOrMatIOn FIreplace lOcatIOn Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.e. blower, wall switch, or remote control) are desired. Consult your local building code agency to ensure compliance with local codes, including permits and inspections.
  • Page 8: Clearances To Combustibles

    WDV Series Gas Fireplace clearances tO cOMBustIBles Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. the appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance.
  • Page 9: Secure Fireplace To Floor Or Framing

    secure FIreplace to FlOOr or FraMInG The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6. Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing.
  • Page 10: Installation Precautions

    WDV Series Gas Fireplace read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life. InstallatIOn precautIOns Consult local building codes before beginning the installation.
  • Page 11: Installation Planning

    Vent InstallatIOn InstallatIOn plannInG There are two basic types of direct-vent installation: • Horizontal Termination • Vertical Termination It is important to select the proper length of vent pipe for the type of termination you choose. It is also important to note the wall thickness. FOr hOrIZOntal terMInatIOn Select the amount of vertical rise desired.
  • Page 12: Venting Installation

    WDV Series Gas Fireplace FOr hOrIZOntal terMInatIOn Vent Terminal Figure 8 - Horizontal Vent Termination Location MInIMuM DIstances A = Clearance above the grade, a veranda, porch, deck, or balcony [*12" (305 mm) minimum]. B = Clearance to window or door that may be opened [*12" (305 mm) minimum]. C = Clearance to permanently closed window [*minimum 12"...
  • Page 13: How To Use The Vent Graph

    VentInG InstallatIOn terMInatIOn clearances FOr BuIlDInGs WIth cOMBustIBle anD nOncOMBustIBle exterIOrs G=6" (152mm) Combustible – 6" (152 mm) Noncombustible – 2" (51 mm) Inside Corner G = Combustible 24"(610mm) Noncombustible 18"(457mm) Balcony with No Side Wall Figure 9 - Allowable Venting Chart hOW tO use the Vent Graph The Vent Graph should be read in conjunction with the following vent installation instructions to determine the...
  • Page 14: Vertical/Horizontal Termination Configurations

    WDV Series Gas Fireplace VertIcal/hOrIZOntal terMInatIOn cOnFIGuratIOns since it is very important that the venting system main- tain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent con- figurations apply and must be strictly adhered to. The Vent Graph, showing the relationship between vertical and horizontal side wall venting, will help to determine the various dimensions allowable.
  • Page 15: Below Grade Installation

    VentInG InstallatIOn A  10’ 90° Elbow = 3' A + B = 17' Maximum 10’ FP2426 Figure 14 - Maximum Vent Run with Elbows FP2426 max vent run w/elbows Example: Elbow 1 = 90° Elbow 2 = 45° Elbow 3 = 45° Elbow 4 = 90°...
  • Page 16: Venting Installation

    WDV Series Gas Fireplace Foundation Recess Watertight Seal Around Pipe Figure 17 - Snorkel Installation, Recessed Foundation FP1966 • Do not back fill around snorkel. snorkel • a clearance of at least 4" must be maintained between the snorkel and the soil.
  • Page 17: Installation For Vertical Termination

    VentInG InstallatIOn InstallatIOn FOr VertIcal terMInatIOn 1. Determine the route your vertical venting will take. If ceiling joist, roof rafters or other framing will obstruct the venting system, consider an offset. Refer to Figure 20 to avoid cutting load bearing members. For optimal flame appearance, a restrictor disk is necessary on straight vertical runs of 10' of more.
  • Page 18 WDV Series Gas Fireplace 3. Cut a hole in the roof using the locating hole as a center point. (Cover any exposed open vent pipes before cutting hole in roof). The 10Z\x"x10Z\x" (241 x 241 mm) hole must be measured on the horizontal. Actual length may be larger depending on the pitch of the roof.
  • Page 19: Flex Vent Installation

    Flex Vent InstallatIOn 1. Flexible UL1777 listed venting may be used in any venting application where rigid direct vent components can be used. all restrictions, clearances and allowances that pertain to the rigid piping apply to the flexible venting. Flex kits may not be modified. Flex kits may be added to the end of a vent run made of rigid vent sections using pipe manufacturer's approved flex to pipe adapters.
  • Page 20: Pipe Connection

    WDV Series Gas Fireplace 2. Install firestop spacers, Figure 26, when penetrating ceiling, attic spaces, or walls. 3. Do not allow the flexible vent to bend in radius tighter than 5" (127 mm). Figure 25 4. Horizontal runs of flexible vent shall be supported at maximum 2 foot intervals; vertical runs, five feet intervals.
  • Page 21: Fireplace Installation

    FIreplace InstallatIOn checK Gas type Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit. InstallInG Gas pIpInG tO FIreplace lOcatIOn a qualified installer or service person must connect appliance to gas supply.
  • Page 22 WDV Series Gas Fireplace Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. nOte: The gas line connection may be made using 1/2" rigid tubing or an approved flex connector. Since some municipalities have additional local codes it is always best to consult your local authorities and the current edition of the National Fuel Gas Code ANSI.Z223.1, NFPA54.
  • Page 23: Check Gas Pressure - Signature Command

    sIGnature cOMManD - checK Gas pressure and electrIcal InstallatIOn 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, stOp! Do not install the appliance.
  • Page 24: Command Center Wall Installation

    sIGnature cOMManD OptIOnal Wall cOMManD center and BlOWer systeM WDV Series Gas Fireplace BLACK Opt. Blower Opt. Aux. Electrical connections should only be performed by a qualified, licensed electri- cian. Main power supply must be turned off before performing service. Only a qualified service person should service and repair the fireplace.
  • Page 25: Optional Fan/Blower Systems

    sIGnature cOMManD - OptIOnal Fan BlOWer systeM a/c WIrInG tO junctIOn BOx IMpOrtant: always check local building codes. this installation must comply with local regulations as well as the national electric code. WIrInG 1. Before installing the blower, wire the receptacle into an electrical circuit.
  • Page 26: Glass Frame Removal

    WDV Series Gas Fireplace Glass FraMe reMOVal 1. Remove the front access door by lifting up and sliding the two (2) spring hinge pins inward and lifting off. 2. Rotate the three (3) cam levers in the lower access area 90° clockwise. 3.
  • Page 27: Stone & Glass Placement

    stOne & Glass placeMent stOne & Glass placeMent 1. For best results, place the stones first. 2. Place the stones randomly against the stone stop bracket, in front of and behind the burner. cautIOn: Do not allow stones to sit directly on burner or in flame. Figure 37 3.
  • Page 28: For Your Safety Read Before Lighting

    WDV Series Gas Fireplace FOr yOur saFety reaD BeFOre lIGhtInG a. This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the instructions for match lighting. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
  • Page 29: Operating Instructions

    sIGnature cOMManD - OperatInG InstructIOns OperatInG InstructIOns 1. stOp! Read the safety information above. 2. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3. With five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, stOp! Follow "B"...
  • Page 30: Battery Installation

    WDV Series Gas Fireplace Features command center • Easy Access Function Operation and System Configura- tion • Operation Confirmation/Fault Diagnostic Indications (LED/ Buzzer) • ON/OFF/HI/Low Operation control Board • Electronic Ignition • Pilot Lockout safety feature • Electric Power Regeneration from Thermopile to save bat- tery •...
  • Page 31: System Configuration/Setup

    sIGnature cOMManD systeM OperatIOn InstructIOns systeM cOnFIGuratIOn/setup System configuration/setup is done on the Command Center. Intermittent/standing pilot setup (Default intermittent) 1. Holding the ON button on the Command Center while turning on the master switch will toggle between standing pilot and intermittent pilot. 2.
  • Page 32: Led Indication

    WDV Series Gas Fireplace cOMManD center FunctIOns/OperatIOn turning on the fireplace 1. Turn on the master switch and wait for a beep. 2. Press the ON button on the Command Center. Pilot will light and burner will come on High setting. pilot safety lockout Function 1.
  • Page 33: Remote Control Operation

    reMOte cOntrOl OperatIOn reMOte transMItter OperatIOns General Figure 39 The RFSC Remote Control has two (2) operating modes: Manual and Thermostatic. The control system can be set to a temperature range between 45° F and 90° F. The blower speed, light, rear burner shut down and flame height can be adjusted in either the manual and thermostatic mode.
  • Page 34 WDV Series Gas Fireplace Flame height setting for thermostatic Mode Figure 43 1. Hold AUTO button for five (5) seconds and one number and flame icon will appear in LCD screen. 2. Use the ON / ▲ or OFF / ▼ button to set the desired flame height to 1 (min.) 2 (medium) or 3 (max.).
  • Page 35: Low Battery Detection

    reMOte cOntrOl OperatIOn On/OFF aux control (Optional) Figure 47 1. Press AUX button once to turn ON. AUX shows on the LCD. 2. Press AUX button again to turn OFF. AUX icon disappears. low Battery Detection Figure 48 1. Battery voltage is checked once a minute. When the battery voltage drops to a certain level, the low-battery icon will display on LCD, and the transmitter will turn off the fire- place.
  • Page 36: Cleaning And Maintenance

    WDV Series Gas Fireplace turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season Burner, pIlOt anD cOntrOl cOMpartMent Keep the control compartment, stones and burner areas surrounding the stones clean by vacuuming or brushing at least twice a year.
  • Page 37: Vent System

    cleanInG anD MaIntenance Vent systeM The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow.
  • Page 38: Signature Command System

    WDV Series Gas Fireplace sIGnature cOMManD systeM OPERATION Install batteries and/or plug in the AC board No beep in about 8 seconds Flip the master switch (rocker switch) to the ON position No beep Press the ON button on the Command Center no sound from the valve indicating pilot solenoid open...
  • Page 39: Replacement Parts

    replaceMent parts FIreBOx cOMpOnents anD accessOrIes Item Description Bulb Bulb Socket Glass Frame Assembly Junction Box Assembly (not shown) Panel, Access, Door accessories / Field Installed Options Porcelain Panels Blower Kit (Signature Command System) Aged Driftwood 78D0011 qty. 780012 DVW firebox parts WDV Series Gas Fireplace WDV500 78D0007K...
  • Page 40: Signature Command System

    WDV Series Gas Fireplace replaceMent parts sIGnature cOMManD systeM 780012 DVW SG parts 6/09 78D0011...
  • Page 41 replaceMent parts sIGnature cOMManD systeM Item Description Gas Valve Assembly Pilot Assembly Control Box Command Center Tube, Tee to Venturi Tube, Tee to Valve Flexhose w/Shutoff Valve Injector Burner Assembly Venturi Air Shutter (not shown) Wire Valve/Control (not shown) Wire AC Module (not shown) Wire Command Ctr.
  • Page 42: Venting Components

    WDV Series Gas Fireplace Vent cOMpOnents 730024 KHLDV vent parts replaceMent parts 78D0011...
  • Page 43 replaceMent parts Vent cOMpOnents FOr 5" x 8" qty./ Item Box Description Horizontal High Wind Termination Cap Horizontal Termination Cap Built-In Vinyl Siding Standoff, Heat Deflector, Firestop, 90° Elbow and Adjustable Pipe 11" to 14 " Horizontal Termination Cap w/Built-In Vinyl Siding Standoff, Heat Deflector, Firestop, Flexible Pipe 20"...
  • Page 44: Stones

    WDV Series Gas Fireplace stOnes Item Description White Stone #1 Light Gray Stone #2 Dark Gray Stone #3 Brown Stone #4 Sand Stone #5 Tan Stone #6 qty. replaceMent parts WDV500 78D0122K 78D0123K 78D0124K 78D0125K 78D0126K 78D0127K 78D0011...
  • Page 45 WDV Series Gas Fireplace 78D0011...
  • Page 46: Requirements For The Commonwealth Of Massachusetts

    requirements for the commonwealth of WDV Series Gas Fireplace Massachusetts This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. note regarding Vented products Flex line installation must not exceed 36 inches and must have a T shutoff valve.
  • Page 47: Limited Lifetime Warranty Policy

    lIMIteD lIFetIMe Warranty pOlIcy lIFetIMe Warranty The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Com- bustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners. FIVe year Warranty The following components are warranted five (5) years to the original owner, subject of proof of purchase: Ceramic Fiber Logs.
  • Page 48: Efficiency Ratings

    efficiency ratings Model enerGuide ratings Fireplace efficiency (%) WDV500NTSC WDV500PTSC Mhsc 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com...

Table of Contents